Related Experiment Video
Updated: Jan 26, 2026

Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
Published on: August 21, 2019
Automated drosophila heartbeat counting based on image segmentation technique on optical coherence tomography
Chia-Yen Lee1, Hao-Jen Wang2,3, Jheng-Da Jhang2
1Department of Electrical Engineering, National United University, Miaoli, ROC, Taiwan. leecyya@gmail.com.
Abstract:
Drosophila and human cardiac genes are very similar. Biological parametric studies on drosophila cardiac have improved our understanding of human cardiovascular disease. Drosophila cardiac consist of five circular chambers: a conical chamber (CC) and four ostia sections (O1-O4). Due to noise and grayscale discontinuity on optical coherence tomography (OCT) images, previous researches used manual counting or M-mode to analyze heartbeats, which are inefficient and time-consuming. An automated drosophila heartbeat counting algorithm based on the chamber segmentation is developed for OCT in this study. This algorithm has two parts: automated chamber segmentation and heartbeat counting. In addition, this study proposes a principal components analysis (PCA)-based supervised learning method for training the chamber contours to make chamber segmentation more accurate. The mean distances between the conical, second and third chambers attained by the proposed algorithm and the corresponding manually delineated boundaries defined by two experts were 1.26 ± 0.25, 1.47 ± 1.25 and 0.84 ± 0.60 (pixels), respectively. The area overlap similarities were 0.83 ± 0.09, 0.75 ± 0.11 and 0.74 ± 0.12 (pixels), respectively. The average calculated heart rates of two-week and six-week drosophila were about 4.77 beats/s and 4.73 beats/s, respectively, which was consistent with the results of manual counting.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Distribution Reliability and Automation

