Radial heterojunction based on single ZnO-CuxO core-shell nanowire for photodetector applications
Andreea Costas1, Camelia Florica2, Nicoleta Preda3
1National Institute of Materials Physics, Multifunctional Materials and Structures Laboratory, Functional Nanostructures Group, 405A Atomistilor Street, 077125, Magurele, Ilfov, Romania. andreea.costas@infim.ro.
Abstract:
ZnO-CuxO core-shell radial heterojunction nanowire arrays were fabricated by a straightforward approach which combine two simple, cost effective and large-scale preparation methods: (i) thermal oxidation in air of a zinc foil for obtaining ZnO nanowire arrays and (ii) radio frequency magnetron sputtering for covering the surface of the ZnO nanowires with a CuxO thin film. The structural, compositional, morphological and optical properties of the high aspect ratio ZnO-CuxO core-shell nanowire arrays were investigated. Individual ZnO-CuxO core-shell nanowires were contacted with Pt electrodes by means of electron beam lithography technique, diode behaviour being demonstrated. Further it was found that these n-p radial heterojunction diodes based on single ZnO-CuxO nanowires exhibit a change in the current under UV light illumination and therefore behaving as photodetectors.
Related Concept Videos
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Nucleosome Core Particle
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their primary aim is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. On the other hand, they must allow polymerase enzymes to access histone-bound DNA during...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Photoluminescence: Applications


