Mario Djukelic1,2, David Waterhouse3, Ryan Toh3
1Department of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.
Introduction:
The aim of this study was to evaluate the suitability of using cone-beam computed tomography (CBCT) obtained with a mobile C-arm X-ray fluoroscopy unit as a single modality for planning of high-dose-rate (HDR) prostate brachytherapy treatments.
Methods:
The feasibility of using CBCT images obtained using a Siemens Arcadis Orbic 3D mobile C-arm was evaluated. A retrospective clinical study was undertaken of six participants undergoing HDR prostate brachytherapy. Plans generated using images from a Toshiba Aquilion One LB CT were compared with those generated using CBCT images. After rigid spatial registration, the plans were compared based on various parameters such as dose-volume histograms, overlap quantities and metrics, and dose constraints.
Results:
Provided they were within the limited field of view, the brachytherapy catheters and fiducial markers were clearly visible in the CBCT images and thus, localisable and identifiable in the treatment planning process. The Siemens CBCT underestimated CT numbers leading to poorer tissue contrast which exacerbated the difficulties in delineation of the target tumour and the surrounding organs at risk. Between CT- and CBCT-based plans, the mean difference of CTV-D90 was 1.58 Gy, CTV-V100 was 12.13%, rectum-V80 was 0.06% and urethra-V120 was -0.70%.
Conclusion:
It was not feasible to solely utilise the Siemens Arcadis Orbic 3D for HDR prostate brachytherapy treatment planning due to suboptimal organ delineation. However, the methods in this study could be used to evaluate other mobile CBCT imaging devices for feasibility in HDR brachytherapy treatment planning since the results indicated that it may not be necessary to have standard quality CT images for treatment planning.
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Dose Size and Dosing Frequency: Determination Methods