Reproducibility of normalized apparent diffusion coefficient measurements on 3.0-T diffusion-weighted imaging of
1Department of Medical Imaging, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, PR China.
Abstract:
To prospectively compare the reproducibility of normal pancreas-normalized apparent diffusion coefficient (ADC) measurements for the normal pancreas and mean normalized ADCs at different pancreas anatomic locations.In total, 22 healthy volunteers underwent pancreatic 3.0-T magnetic resonance (MR) imaging, including axial diffusion-weighted (DW) imaging with 3 b values used (0, 400, and 800 s/mm) and with the respiratory-triggered (RT) technique. The mean ADCs from 3 regions of interest (ROIs) in 5 anatomic locations (head [H], body [B], and tail [T] of pancreas and spleen [S] and erector spinae muscles [M]) were calculated. The pancreas-normalized ADC was defined as the ratio of the ADC for the pancreas to the ADC for the spleen or erector spinae muscle. Reproducibility of ADCs and normalized ADCs was assessed by the Bland-Altman method. The ADC and normalized ADC data were analyzed by repeated-measures ANOVA.Mean ADC and normalized ADC values did not differ (P >.05) with repeated measurements at the different pancreas anatomic locations. Reproducibility of pancreas-normalized ADC measurements in each of the 3 pancreatic anatomic locations was better with the erector spinae muscle rather than the spleen used as a reference. Mean ADC and normalized ADC values significantly differed between the 3 pancreatic segments (H: 1.36 × 10 mm/s, B: 1.38 × 10 mm/s, T: 1.25 × 10 mm/s, P = .022; H/S: 1.75, B/S: 1.78, T/S: 1.59, P = .009; H/M: 0.91, B/M: 0.95, T/M: 0.85, P = .008). Mean ADC values and normalized ADC values showed a trend to decrease from the pancreatic head to tail.Our preliminary results suggest that normalized ADC measurements for the pancreas show good intra- and interobserver reproducibility, the erector spinae muscle is a better choice than the spleen for calculating normalized ADC values for the pancreas, and the normalized ADC values are lower for the pancreatic tail than other pancreatic segments.
More Related Videos
11:43Easy Measurement of Diffusion Coefficients of EGFP-tagged Plasma Membrane Proteins Using k-Space Image Correlation Spectroscopy
Published on: May 10, 2014
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Diffusion
Diffusion
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Normal Distribution