Related Experiment Video
Updated: Jan 26, 2026

Coincubation Assay for Quantifying Competitive Interactions between Vibrio fischeri Isolates
Published on: July 22, 2019
Establishment of an EC50 database of pesticides using a Vibrio fischeri bioluminescence method
Snezana Efremova Aaron1, Katerina Tosheska-Trajkovska1, Svetlana Cekovska1
1Department of Medical and Experimental Biochemistry, Faculty of Medicine, Ss. Ciril & Metodius University, Skopje, R. Macedonia.
Abstract:
An EC50 database was established to assess the acute toxicity of 16 PESTANAL pesticide standards and of seven pesticide commercial formulations using a Vibrio fischeri bioluminescence method. Half maximal effective concentration (EC50 ) is defined as the concentration of pollutant (in this case, pesticide) destroying 50% of the bacteria population and causing 50% bioluminescence inhibition, after a specified exposure time. Linear curves of bioluminescence inhibition versus pesticide concentration and EC50 values were obtained for exposure times (t) of 5 or 15 min for these pesticides. The EC50 values ranged from 6.90 × 10-4 to 0.83 mg/ml (t = 5 min), and from 9.00 × 10-4 to 0.37 mg/ml (t = 15 min) for pesticide standards, plus from 0.0077 to 0.74 mg/ml (t = 5 min), and from 0.0076 and 0.57 mg/ml (t = 15 min) for pesticide commercial formulations. The EC50 database allowed classification of the pesticides under study into three categories according to their toxicity: very toxic, toxic and moderately toxic. These results demonstrated that the establishment of an EC50 database and of linear curves of bioluminescence inhibition versus the pesticide concentration resulted in very important and irreplaceable tools to estimate the global and individual toxicity of pesticides present in environmental samples.
More Related Videos
Related Concept Videos
Clinically Relevant Drug Product Specifications: Methods of Establishment
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...
The Scientific Method
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

