Related Experiment Video
Updated: Jan 26, 2026

Optimized Management of Endovascular Treatment for Acute Ischemic Stroke
Published on: January 18, 2018
Extending the time window for intravenous thrombolysis in acute ischemic stroke using magnetic resonance
Peter Ringleb1, Martin Bendszus2, Erich Bluhmki3
11 Department of Neurology, University of Heidelberg, Heidelberg, Germany.
Background:
Intravenous thrombolysis with alteplase within a time window up to 4.5 h is the only approved pharmacological treatment for acute ischemic stroke. We studied whether acute ischemic stroke patients with penumbral tissue identified on magnetic resonance imaging 4.5-9 h after symptom onset benefit from intravenous thrombolysis compared to placebo.
Methods:
Acute ischemic stroke patients with salvageable brain tissue identified on a magnetic resonance imaging were randomly assigned to receive standard dose alteplase or placebo. The primary end point was disability at 90 days assessed by the modified Rankin scale, which has a range of 0-6 (with 0 indicating no symptoms at all and 6 indicating death). Safety end points included death, symptomatic intracranial hemorrhage, and other serious adverse events.
Results:
The trial was stopped early for slow recruitment after the enrollment of 119 (61 alteplase, 58 placebo) of 264 patients planned. Median time to intravenous thrombolysis was 7 h 42 min. The primary endpoint showed no significant difference in the modified Rankin scale distribution at day 90 (odds ratio alteplase versus placebo, 1.20; 95% CI, 0.63-2.27, P = 0.58). One symptomatic intracranial hemorrhage occurred in the alteplase group. Mortality at 90 days did not differ significantly between the two groups (11.5 and 6.8%, respectively; P = 0.53).
Conclusions:
Intravenous alteplase administered between 4.5 and 9 h after the onset of symptoms in patients with salvageable tissue did not result in a significant benefit over placebo. (Supported by Boehringer Ingelheim, Germany; ISRCTN 71616222).
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Resonance
Imaging Studies V: Intravenous Urography and Retrograde Pyelography