Related Experiment Video
Updated: Jan 26, 2026

Production of Single Tracks of Ti-6Al-4V by Directed Energy Deposition to Determine the Layer Thickness for Multilayer Deposition
Published on: March 13, 2018
Surface properties and cytocompatibility of Ti-6Al-4V fabricated using Laser Engineered Net Shaping
Revathi A1, Das Mitun2, Vamsi K Balla2
1School of Biosciences and Technology (SBST), VIT University, Vellore, TN, India.
Abstract:
Direct laser deposition (DLD) is one of the rapidly emerging laser-based additive manufacturing (LBAM) process. Laser Engineered Net Shaping (LENS) is one such DLD technique which was employed to fabricate one of the widely used Ti-6Al-4V implant material with enhanced surface-related properties compared to the wrought sample (commercially available). Wear and corrosion behavior of LENS fabricated Ti-6Al-4V (L-Ti64) was characterized using low-frequency reciprocatory wear tester and potentiostat. Sample hardness was determined using Vickers's microhardness test. Adhesion and morphology of Human mesenchymal stem cells (hMSCs) on the samples were examined using Scanning Electron Microscopy (SEM) and fluorescence microscope whereas the quantification of live cells was determined using MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-Diphenyltetrazolium Bromide) assay. Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) was used to determine the concentration of leached-out metal ions during wear test. All the above mentioned surface-related properties were compared to that of wrought Ti-6Al-4V (W-Ti64) to standardize the efficiency of LENS-fabricated materials (L-Ti64) when compared to its wrought counterpart. The results clearly indicated stable passive behavior of L-Ti64, which was evident from the lower corrosion rate and high passive range obtained. L-Ti64 exhibited improved hardness level than W-Ti64 by 8% which enhanced the wear resistance and also prevented the release of wear debris. However, in presence of FBS, coefficient of friction (COF) increased by about 21 and 33% for L-Ti64 and W-Ti64 respectively, which inturn accelerated the wear rate of both the samples. Low cytotoxicity and well spread morphology of human Mesenchymal Stem Cells (hMSC's) affirmed higher level of biocompatibility of both the samples. However, no significant differences in the cellular behaviors were observed.
Related Concept Videos
Molecular Shape and Polarity
VSEPR Theory and the Basic Shapes
Molecular Shapes
Two regions of electron density in a diatomic...
What is Genetic Engineering?
First Derivatives and the Shape of a Graph
Second Derivatives and the Shape of a Graph

