A novel generic dictionary-based denoising method for improving noisy and densely packed nuclei segmentation in 3D

Lamees Nasser1,2, Thomas Boudier3,4

  • 1Sorbonne Université, UPMC Univ Paris 06, UJF, CNRS, IMT, NUS, Image and Pervasive Access Lab (IPAL), 138632, Singapore, Singapore. lames_khalaf@h-eng.helwan.edu.eg.

Scientific Reports
|April 6, 2019
PubMed

Related Concept Videos

Dense Connective Tissue01:13

Dense Connective Tissue

Dense connective tissue contains more collagen fibers than loose connective tissue. As a consequence, it displays greater resistance to stretching. There are two major categories of dense connective tissue— regular and irregular.
Dense Regular Connective Tissue
In dense regular connective tissue, fibers are arranged parallel to each other, enhancing its tensile strength and resistance to stretching in the direction of the fiber orientations. Ligaments and tendons are made of dense regular...
11.9K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
20.1K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
321
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
11.1K
Atomic Nuclei: Nuclear Spin01:08

Atomic Nuclei: Nuclear Spin

All atomic particles possess an intrinsic angular momentum, or 'spin'. Electrons, protons, and neutrons each have a spin value of ½, although protons and neutrons in nuclei may have higher half-integer spins owing to energetic factors.
Atomic nuclei have a net nuclear spin, , which can have an integer or half-integer value. In atomic nuclei, the spins of protons are paired against each other but not with neutrons, and vice versa. Consequently, an even number of protons does not contribute to...
5.0K