Validation of a low-dose contrast 64-slice cardiac computed tomography angiography protocol for aortic valve annulus
Elizabeth M Holper1,2, Deepika Gopal1, Alexandria Biberstein2
1The Heart Hospital Baylor PlanoPlanoTexas.
Abstract:
Cardiac computed tomography angiography (CCTA) is the gold standard for accurately sizing the aortic valve annulus prior to aortic valve replacement. A reduction of contrast volume administered for CCTA, without sacrificing image quality, is desirable. Signal-to-noise ratio represents final CCTA image quality. Consecutive patients referred to CCTA for aortic valve annulus sizing were retrospectively analyzed. Patients were grouped into a low-dose contrast (LDCT) group and traditional dose contrast (TDCT) group. In the LDCT group, contrast dose was <50% of the maximal allowable dose (3.7 × estimated glomerular filtration rate). Guided by a time-density curve, the contrast was administered in a two-stage infusion, and retrospectively gated images were acquired with a 64-multidetector computed tomography scanner. Out of 123 patients (age 80 ± 9 years; 46% female), 65 (52.9%) underwent LDCT and 58 (47.2%) underwent TDCT. Contrast volume was significantly lower in the LDCT group (LDCT 41.2 ± 9.8 vs TDCT 76.2 ± 14.2 mL; P < 0.001). The signal-to-noise ratio of the aortic root was 10.4 ± 4.1 for the LDCT group and 8.4 ± 3.3 for the TDCT group (P = 0.004). Aortic root dimensions could be measured in both LDCT and TDCT groups. In conclusion, LDCT with 64-slice CCTA can effectively size the aortic valve annulus to direct aortic valve replacement while offering reduced contrast exposure.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Dose Size and Dosing Frequency: Determination Methods
Imaging Studies III: Computed Tomography
Reliability and Validity
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses