Related Experiment Video
Updated: Jan 26, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Separation and purification of lanosterol, dihydrolanosterol, and cholesterol from lanolin by high-performance
Hairun Pei1, Xiaotong Ma1, Yan Pan2
1Beijing Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology & Business University, Beijing, P. R. China.
Abstract:
Lanosterol is a potential drug for cataracts treatment, which can reverse the aggregation of intracrystalline proteins. The low concentration in lanolin calls for high-performance separation methods. In this study, a counter-current chromatography dual-mode elution method was developed for the first time to separate and purify lanosterol from hexane extract of lanolin after saponification, in which the column was first eluted with the lower phase as mobile phase in head-to-tail mode, followed by the upper phase in the tail-to-head mode. High purity of lanosterol, dihydrolanosterol, and cholesterol can be obtained simultaneously. A solvent system composed of n-heptane/acetonitrile/ethyl acetate (5:5:1, v/v/v) was selected and optimized via partition coefficient determination. Compounds such as 111 mg lanosterol, 84 mg dihydrolanosterol, and 183 mg cholesterol with high purity of 99.77, 95.71, and 91.43%, respectively, analyzed by high-performance liquid chromatography were obtained within 80 min from 700 mg crude extract from 1.78 g lanolin. The method was also used to improve the purity of commercial lanosterol product from 66.97 to above 99%. Counter-current chromatography could serve as a potential and powerful technique for commercial production of highly pure lanosterol.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Cholesterol: Significance and Regulation
Considering cholesterol and...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...

