Related Experiment Video
Updated: Jan 26, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
A prospective randomized comparison of airway seal using the novel vision-guided insertion of LMA-Supreme® and
André A J van Zundert1,2, Kerstin H Wyssusek3, Anita Pelecanos4
1Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, The University of Queensland, Brisbane, QLD, Australia. vanzundertandre@gmail.com.
Abstract:
The laryngeal mask airways supreme (LMA-Supreme™) and protector (LMA-Protector™) are generally placed blindly, often resulting in a less than optimal position and vision-guided placement has been recommended. This prospective, randomized controlled study compared the efficacy of airway seal by measuring the oropharyngeal leak pressure in 100 surgical patients who underwent a variety of non-thoracic surgery under general anaesthesia, suitable with a supraglottic airway device. Patients were allocated to either the LMA-Supreme (n = 50) or LMA-Protector (n = 50) group. All insertions were performed under vision of a videolaryngoscope using an 'insert-detect-correct-as-you-go' technique with standardized corrective measures. Our primary endpoint, mean oropharyngeal leak pressure, was significantly higher in the LMA-Protector (31.7 ± 2.9 cm H2O) compared to the LMA-Supreme (27.7 ± 3.5 cm H2O) group (mean difference 4.0 cm H2O, 95% confidence interval (CI) 2.7-5.3 cm H2O, p < 0.001) after achieving a near-optimal fibreoptic position in the LMA-Protector (94%) and LMA-Supreme (96%) groups. No statistically significant differences were shown for secondary outcomes of alignment, number of insertion attempts and malpositions, and final anatomical position as scored by fibreoptic evaluation. Corrective manoeuvres were required in virtually all patients to obtain a correct anatomically positioned LMA. Position outcomes of the two devices were similar except for the proportion of procedures with folds in the proximal cuff (90% LMA-Supreme vs. 2% LMA-Protector, p < 0.001), the need for intracuff pressure adjustments (80% LMA-Supreme vs. 48% LMA-Protector, p = 0.001) and size correction (18% LMA-Supreme vs. 4% LMA-Protector, p = 0.025). In conclusion, a higher oropharyngeal leak pressure can be achieved with LMA-Protector compared to LMA-Supreme with optimal anatomical position when insertion is vision-guided.
Related Concept Videos
Vision
Color Vision
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...
The Sense of Self: Reflected Self-Appraisal and Social Comparison

