Development of a progesterone-specific IgE assay for diagnosing patients with suspected progestogen hypersensitivity
Debajyoti Ghosh1, Jonathan A Bernstein1
1Department of Internal Medicine, Division of Immunology, Allergy Section, University of Cincinnati, Cincinnati, OH.
Background:
Progesterone hypersensitivity (PH) manifests as a spectrum of allergic symptoms during the luteal phase of the menstrual cycle. Confirming progesterone-specific immunoglobulin E (IgE; sIgE) by skin testing is unreliable because of irritant responses.
Objective:
To develop a progesterone sIgE assay to assist in diagnosing PH.
Methods:
A progesterone-bovine serum albumin (BSA) conjugate was characterized and used to analyze sera collected from women in our center with suspected PH in a 1-batch enzyme-linked immunosorbent assay (ELISA) to establish high, low and negative cut-points. Sera collected from healthy nonatopic female subjects and from women with classical PH symptoms were included as negative and positive controls, respectively. Values exceeding the average negative control (OD + 3× the standard deviation) were considered positive. These cut-points were subsequently used to establish positive and negative results for serum from women with suspected PH received from other centers. A subset of high positive sera was used for ELISA-inhibition and in a beta-hexosaminidase mediator release assay to evaluate the specificity and functional relevance of progesterone-specific serum IgE, respectively. The numbers of true negative, false negative, true positive, and false positive samples were determined.
Results:
The direct progesterone sIgE ELISA results ranged from high positive to low positive and negative compared with healthy nonatopic control sera. Enzyme-linked immunosorbent assay inhibition and beta-hexosaminidase mediator release confirmed specificity and functional relevance of progesterone-sIgE, respectively. The sensitivity, specificity positive predictive values and negative predictive values were found to be 82%, 100%, 86%, and 100%, respectively, using the mediator release assay results as the gold standard.
Conclusion:
This assay has a good specificity and positive predictive value for screening women with suspected PH for progesterone sIgE.
More Related Videos
Related Concept Videos
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Allergic Reactions
Antiasthma Drugs: Mast Cell Stabilizers and Anti-IgE Drugs
Mast cell stabilizers, such as cromolyn (also known as sodium cromoglycate) and nedocromil (Tilade), are effective drugs in asthma management. These stabilizers hinder histamine release by skillfully obstructing the activation of mast cells and other cellular entities. Notably, they navigate this task without...
Sustainable Development
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...