Task-specific solid-phase microextraction based on ionic liquid/polyhedral oligomeric silsesquioxane hybrid coating

Ning Zhang1, Lishen Su1, Suning Man1

  • 1Key Laboratory for Analytical Science of Food Safety and Biology (Ministry of Education & Fujian Province), PR China; College of Chemistry, Fuzhou University, Fuzhou, 350116, PR China.

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Molecular and Ionic Solids02:54

Molecular and Ionic Solids

Crystalline solids are divided into four types: molecular, ionic, metallic, and covalent network based on the type of constituent units and their interparticle interactions.
Molecular Solids
Molecular crystalline solids, such as ice, sucrose (table sugar), and iodine, are solids that are composed of neutral molecules as their constituent units. These molecules are held together by weak intermolecular forces such as London dispersion forces, dipole-dipole interactions, or hydrogen bonds, which...
20.0K
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
2.5K
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
2.3K
Molecular Comparison of Gases, Liquids, and Solids02:26

Molecular Comparison of Gases, Liquids, and Solids

Particles in a solid are tightly packed together (fixed shape) and often arranged in a regular pattern; in a liquid, they are close together with no regular arrangement (no fixed shape); in a gas, they are far apart with no regular arrangement (no fixed shape). Particles in a solid vibrate about fixed positions (cannot flow) and do not generally move in relation to one another; in a liquid, they move past each other (can flow) but remain in essentially constant contact; in a gas, they move...
54.5K
Aromatic Hydrocarbon Anions: Structural Overview01:18

Aromatic Hydrocarbon Anions: Structural Overview

Neutral hydrocarbons like cyclopentadiene with an odd number of carbon atoms and one intervening CH2 group in the ring are not aromatic. Cyclopentadiene with 4 π electrons does not satisfy the 4n + 2 π electron rule. Additionally, the intervening CH2 group is sp3 hybridized and lacks a vacant p orbital, thereby interrupting the overlap of p orbitals in a continuous manner and preventing the delocalization of π electrons throughout the ring.
Due to the absence of continuous...
3.6K