Related Experiment Video
Updated: Jan 26, 2026

Combination of Adhesive-tape-based Sampling and Fluorescence in situ Hybridization for Rapid Detection of Salmonella on Fresh Produce
Published on: October 18, 2010
Hyperspectral Imaging Based Method for Rapid Detection of Microplastics in the Intestinal Tracts of Fish
Yituo Zhang1, Xue Wang1, Jiajia Shan1
1School of Food and Environment , Dalian University of Technology , Panjin 124221 , China.
Abstract:
Microplastics (MPs) in aquatic organisms are raising increasing concerns regarding their potential damage to ecosystems. To date, Raman and Fourier transform infrared spectroscopy techniques have been widely used for detection of MPs in aquatic organisms, which requires complex protocols of tissue digestion and MP separation and are time- and reagent-consuming. This novel approach directly separates, identifies, and characterizes MPs from the hyperspectral image (HSI) of the intestinal tract content in combination with a support vector machine classification model, instead of using the real digestion/separation protocols. The procedures of HSI acquisition (1 min) and data analysis (5 min) can be completed within 6 min plus the sample preparation and drying time (30 min) where necessary. This method achieved a promising efficiency (recall >98.80%, precision >96.22%) for identifying five types of MPs (particles >0.2 mm). Moreover, the method was also demonstrated to be effective on field fish from three marine fish species, revealing satisfying detection accuracy (particles >0.2 mm) comparable to Raman analysis. The present technique omits the digestion protocol (reagent free), thereby significantly reducing reagent consumption, saving time, and providing a rapid and efficient method for MP analysis.
Related Concept Videos
Osmoregulation in Fishes
Anatomy of the Intestines
Small Intestines
The small intestine is an ~7 meter-long tube with an inner diameter of just 2.5 cm. Since most nutrients are absorbed here, the inner lining of the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Small Intestine
The small intestine is divided into three main sections - the duodenum, jejunum, and ileum. The duodenum, approximately 25 cm long, is nearest the stomach. It acts as a 'mixing bowl,' where chyme (partially digested food) blends with digestive enzymes from the pancreas and liver. The duodenum's unique...
Large Intestine
The ileocecal sphincter, a mucous membrane fold, guards the opening from the ileum to the large intestine. This valve permits material from the small intestine to pass into the large intestine. Attached to the ileocecal valve is the cecum. This small pouch, approximately 6 cm long, has a twisted, coiled tube known as...

