Related Experiment Video
Updated: Jan 26, 2026

Lavage-induced Surfactant Depletion in Pigs As a Model of the Acute Respiratory Distress Syndrome ARDS
Published on: September 7, 2016
Nasal High-Frequency Oscillatory Ventilation in Preterm Infants With Respiratory Distress Syndrome and ARDS After
Long Chen1, Li Wang2, Juan Ma2
1Department of Neonatology, Children's Hospital of Chongqing Medical University, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing, China; China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Chongqing, China; Chongqing Key Laboratory of Pediatrics, Chongqing, China.
Background:
Nasal high-frequency oscillatory ventilation (NHFOV) has been described as supplying the combined advantages of nasal CPAP (NCPAP) and HFOV. However, its effect on preterm infants needs to be further elucidated. Our objective was to assess whether NHFOV could reduce intubation and Pco2 levels as compared with NCPAP during the postextubation phase in preterm infants.
Methods:
This was a single-center, randomized, controlled trial, and it was registered at clinicaltrials.gov (NCT03140891) and conducted between May 2017 and May 2018. Ventilated infants born at less than 37 weeks' gestational age and ready to be extubated were included and randomized to either the NHFOV or NCPAP group. Primary outcomes were the incidence of reintubation within 1 week and the Pco2 level within 6 h.
Results:
A total of 206 preterm infants were included. Of them, 127 (61.7%) were diagnosed with respiratory distress syndrome, 53 (25.7%) with ARDS, and 26 (12.6%) with both respiratory distress syndrome and ARDS. Comparing with NCPAP, NHFOV significantly reduced the reintubation rate (16:87 vs 35:68; 95% CI, 0.18-0.70; P = .002), especially in the subgroup with a gestational age of ≤ 32 weeks (12:34 vs 25:20; 95% CI, 0.12-0.68; P = .004). The Pco2 level was also significant lower in the NHFOV group (49.6 ± 8.7 vs 56.9 ± 9.9; 95% CI, -9.95 to -4.80; P = < .001). Moreover, NHFOV significantly reduced the reintubation rate in preterm infants with ARDS (10:33 vs 21:15; 95% CI, 0.08-0.57; P = .002).
Conclusions:
NHFOV was shown to be superior to NCPAP in avoiding reintubation, especially in very preterm infants and those infants diagnosed with ARDS.
Trial Registry:
ClinicalTrials.gov; No.: NCT03140891; URL: www.clinicaltrials.gov.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Load-frequency control
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...