Newborn Screening for Lysosomal Storage Disorders: Methodologies for Measurement of Enzymatic Activities in Dried
Michael H Gelb1, Zoltan Lukacs2, Enzo Ranieri3
1Departments of Chemistry and Biochemistry, University of Washington, Seattle, WA 98195, USA.
Abstract:
All worldwide newborn screening (NBS) for lysosomal storage diseases (LSDs) is performed as a first-tier test by measurement of lysosomal enzymatic activities in dried blood spots (DBS). The currently two available methodologies used for measurement of enzymatic activities are tandem mass spectrometry (MS/MS) and digital microfluidics fluorimetry (DMF-F). In this chapter we summarize the workflows for the two platforms. Neither platform is fully automated, but the relative ease of workflow will be dependent upon the specific operation of each newborn screening laboratory on a case-by-case basis. We provide the screen positive rate (the number of below cutoff newborns per 100,000 newborns) from all NBS laboratories worldwide carrying out MS/MS-based NBS of one or more LSDs. The analytical precision of the MS/MS method is higher than that for DMF-F as shown by analysis of a common set of quality control DBS by the Centers for Disease Control and Prevention (CDC). Both the MS/MS and DMF-F platforms enable multiplexing of the LSD enzymes. An advantage of MS/MS over DMF-F is the ability to include assays of enzymatic activities and biomarkers for which no fluorimetric methods exist. Advantages of DMF-F over MS/MS are: 1) Simple to use technology with same-day turn-around time for the lysosomal enzymes with the fastest rates compared to MS/MS requiring overnight analytical runs.; 2) The DMF-F instrumentation, because of its simplicity, requires less maintenance than the MS/MS platform.
Related Concept Videos
Lysosomes
Storage
Lysosomal Hydrolases
Delivery Pathways to the Lysosome
Endocytosis
In endocytosis, the cell membrane takes up macromolecules and particles from the surrounding medium. Clathrin-mediated...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...