Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Efficacy of the OTSC System in the treatment of GI bleeding and wall defects: a PMCF meta-analysis
Timo Weiland1, Sabrina Rohrer1, Arthur Schmidt2,3
1novineon CRO, Tuebingen, Germany.
Abstract:
Since its market launch in 2007, the endoscopic OTSC clipping system has been the object of intensive clinical research. These data were systematically collected for post-market clinical follow-up (PMCF). The aim of the study was the systematic review of the efficacy and safety of the OTSC System. The PMCF database was systematically searched for clinical data on OTSC therapy of GI hemorrhage (H), acute leaks/perforations (AL) and chronic leaks/fistulae (CL). Major outcomes were successful clip application and durable hemostasis/closure of defects. Comprehensive pooled success proportions were established by meta-analytical methods. Four-hundred-fifty-seven publications were reviewed. Fifty-eight articles comprising 1868 patients fulfilled criteria to be included in the analysis. These consisted of retrospective analyses, prospective observational trials, one randomized-controlled trial (STING) and one quasi-controlled study (FLETRock). The pooled proportion analysis revealed high overall proportions of technical success: H - mean 93.0% [95%CI 90.2-95.4], AL-mean 89.7% [95%CI 85.9-92.9] and CL-mean 83.8% [95%CI 76.9-89.7]. Pooled durable clinical success proportions were: H-mean 87.5% [95%CI 80.5-93.2], AL-mean 81.4% [95%CI 77.0-85.3] and CL-mean 63.0% [95%CI 53.0-72.3]. By pooling all clinical data gained, we conclude that OTSC application in GI hemorrhage and closure of GI lesions is safe and effective in real clinical use.
More Related Videos
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
06:26Meta-analysis of Voxel-Based Neuroimaging Studies using Seed-based d Mapping with Permutation of Subject Images SDM-PSI
Published on: November 27, 2019
Related Concept Videos
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Plant Cell Wall
Self-Efficacy
Directing Effect of Substituents: meta-Directing Groups
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Bacterial Cell Wall