Related Experiment Video
Updated: Jan 26, 2026

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Analysis, modeling, control and operation of an interleaved three-port boost converter for DMPPT systems including PV
Ander González1, Ramón López-Erauskin1, Johan Gyselinck1
1Bio Electro and Mechanical Systems (BEAMS) Department, Université Libre de Bruxelles, 50 Franklin Roosevelt Ave. (CP165/52), B-1050, Brussels, Belgium.
Abstract:
This paper presents the analysis, control and implementation of the interleaved three-port boost converter. The scope of this paper is the interfacing of photovoltaic systems that include storage. A new symmetrical PWM modulation strategy that prevents unwanted switching states without requiring external circuitry is presented. This modulation allows for proper sampling of the measurements, increasing thus their accuracy. Large- and small-signal models of the interleaved and non-interleaved three port boost converters are presented and transfer functions are derived for control design purposes. The different currents in the converter are controlled using control loops that govern the behavior of the converter. These loops are intuitively designed by treating them independently. With the proper loop bandwidth selection, the converter achieves fast response and good reference tracking and is suitable to interface photovoltaic and storage systems with different kinds of loads. The presented models, modulation and control loops are validated through simulation and with experimental results.
Related Concept Videos
Control Systems
At the heart...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...
pV-Diagrams