Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial
Ray Cody Mayo1, Daniel Kent2, Lauren Chang Sen3
1Department of Diagnostic Imaging, Breast Imaging Division, MD Anderson Center, University of Texas, 1515 Holcombe Blvd., Houston, TX, 77030, USA. rcmayo@mdanderson.org.
Abstract:
The aim was to determine whether an artificial intelligence (AI)-based, computer-aided detection (CAD) software can be used to reduce false positive per image (FPPI) on mammograms as compared to an FDA-approved conventional CAD. A retrospective study was performed on a set of 250 full-field digital mammograms between January 1, 2013, and March 31, 2013, and the number of marked regions of interest of two different systems was compared for sensitivity and specificity in cancer detection. The count of false-positive marks per image (FPPI) of the two systems was also evaluated as well as the number of cases that were completely mark-free. All results showed statistically significant reductions in false marks with the use of AI-CAD vs CAD (confidence interval = 95%) with no reduction in sensitivity. There is an overall 69% reduction in FPPI using the AI-based CAD as compared to CAD, consisting of 83% reduction in FPPI for calcifications and 56% reduction for masses. Almost half (48%) of cases showed no AI-CAD markings while only 17% show no conventional CAD marks. There was a significant reduction in FPPI with AI-CAD as compared to CAD for both masses and calcifications at all tissue densities. A 69% decrease in FPPI could result in a 17% decrease in radiologist reading time per case based on prior literature of CAD reading times. Additionally, decreasing false-positive recalls in screening mammography has many direct social and economic benefits.
Related Concept Videos
Reactions at the Benzylic Position: Oxidation and Reduction
Bone Markings
Articulating Projections
Articulating projections are found where two bones meet to form a joint. These structures are usually found at the ends of bones. The largest articulation is a rounded projection called the head, supported by a narrow neck at the ends of...
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Position of Equilibrium in Acid-Base Reactions
Oxidation-Reduction Reactions