Related Experiment Video
Updated: Jan 26, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Precision dose measurement of 125I seed in solid water through SPECT/CT detecting
Hongtao Zhang1, Yansong Liang2, Gang Qiu2
1Department of Radiology, The 4th Affiliated Hospital of Hebei Medical University; Department of Oncology, Hebei General Hospital, Shijiazhuang, China.
Purpose:
The aim of the study is to study the feasibility of gamma-ray-detection-based precision dose measurement of 125I seed brachytherapy in solid water.
Materials And Methods:
Seven group 125I seeds with different activities were put into a hole in the center of solid water individually. Each group had ten seeds, and the seed activity ranged from 1.48 × 107 Bq to 3.7 × 107 Bq. Single-photon emission computed tomography/computed tomography (SPECT/CT) was used to scan the seeds perpendicular to the long axis of the seed, with a slice thickness of 3.75 mm. The radioactive count values (x) of the radioactive concentration around the seeds were collected at a distance of 1-15 mm from the center of the seeds, while the corresponding doses (Y) (Gy) were calculated. SPSS 18.0 was used to analyze the relationship between the count value and the dose.
Results:
With the same seed activity, the count values became smaller according to the distance from the center of the seeds. The count values at the same point had an increasing trend according to the activity. This is similar to the doses calculated at the same point. There was an exponential relationship between the dose around the 125I seeds, and the radioactive count value detected by SPECT/CT. Correlative curves between the dose and radioactive count value detected by SPECT/CT of different-activity 125I seeds were fitted. The formulas of the dose and radioactive count with different seed activity were in the form of Y = b0 (b1)x. The constant b0 ranged from 1.48 to 3.93, according to the seed activity, while b1 was 1.006 for every seed's activity.
Conclusion:
The count value around the 125I seed can be detected accurately by SPECT/CT, and then can be quantified. This study provided useful experiment data for the precision measurement of 125I seed implantation. Radiation detection-based dose measurement may become a new noninvasive technology for the dynamic dosimetry verification method after brachytherapy.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Structures of Solids
Seed Structure and Early Development of the Sporophyte
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...