B lymphocytes protect islet β cells in diabetes prone NOD mice treated with imatinib

Christopher S Wilson1, Jason M Spaeth2, Jay Karp2

  • 1Department of Pediatrics, Ian Burr Division of Endocrinology and Diabetes, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

JCI Insight
|April 10, 2019
PubMed

Imatinib (Gleevec) reverses type 1 diabetes (T1D) in NOD mice and is currently in clinical trials in individuals with recent-onset disease. While research has demonstrated that imatinib protects islet β cells from the harmful effects of ER stress, the role the immune system plays in its reversal of T1D has been less well understood, and specific cellular immune targets have not been identified. In this study, we demonstrate that B lymphocytes, an immune subset that normally drives diabetes pathology, are unexpectedly required for reversal of hyperglycemia in NOD mice treated with imatinib. In the presence of B lymphocytes, reversal was linked to an increase in serum insulin concentration, but not an increase in islet β cell mass or proliferation. However, improved β cell function was reflected by a partial recovery of MafA transcription factor expression, a sensitive marker of islet β cell stress that is important to adult β cell function. Imatinib treatment was found to increase the antioxidant capacity of B lymphocytes, improving reactive oxygen species (ROS) handling in NOD islets. This study reveals a novel mechanism through which imatinib enables B lymphocytes to orchestrate functional recovery of T1D β cells.

Related Concept Videos

Pathophysiology of Diabetes01:20

Pathophysiology of Diabetes

Diabetes mellitus is a chronic metabolic disorder characterized by hyperglycemia. The four categories of diabetes are type 1 diabetes, type 2 diabetes, other specific types of diabetes, and gestational diabetes.
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
3.3K
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
788
Protection of Alcohols02:31

Protection of Alcohols

This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.0K
Protecting Self-Esteem01:27

Protecting Self-Esteem

Self-esteem, a central component of psychological well-being, is actively maintained through various cognitive and behavioral strategies. Individuals employ specific mechanisms to preserve a positive self-concept and mitigate threats to their self-worth, particularly in contexts involving social evaluation or personal feedback. Four primary techniques are commonly used to sustain self-esteem.Manipulating AppraisalsOne prominent strategy involves manipulating appraisals from others. Individuals...
204
Radial System Protection01:23

Radial System Protection

Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
433
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
446