Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration
Related Experiment Video
Updated: Jan 26, 2026

Coherent Anti-Stokes Raman Spectroscopy CARS Application for Imaging Myelination in Brain Slices
Published on: July 22, 2022
Gerhard S Drenthen1, Walter H Backes2, Albert P Aldenkamp3
1School for Mental Health and Neuroscience, Maastricht University Medical Center, P. Debyelaan 25, Maastricht, the Netherlands; Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, P. Debyelaan 25, Maastricht, the Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, Eindhoven, the Netherlands.
Abstract:
Non-invasive quantification of the in vivo myelin content may provide valuable information regarding healthy maturation of the brain, as well as insights into demyelination of several neurological disorders. However, these scans are often long thereby limiting acquisition of large brain parts in clinically feasible acquisition times. Therefore, fast acquisition of whole brain myelin content is important. To avoid errors related to slice-selective pulses, most of the previous whole brain studies on myelin content relied on a 3D acquisition. However, multi-slice (2D) acquisition methods are often faster, and less susceptible to motion artifacts. Therefore, multi-slice approaches can be beneficial in a clinical setting. We investigated the applicability and reproducibility of whole brain multi-slice GRASE myelin-water imaging with post-acquisition slice-profile correction in healthy volunteers (aged 25-32y). The applicability was evaluated using the agreement between the multi-slice GRASE and the reference method for myelin-water imaging, single-slice multi spin-echo (MSE) acquisition. Additionally, we assessed the effect of varying acquisition acceleration using parallel imaging on the reproducibility values. First, the multi-slice myelin-water maps showed good agreement with the single-slice reference method, with a bias of at most 1.2% in absolute MWF values. Second, we found an average within-subject coefficient of variation (CoV) of 5.9% and an average intra-class correlation coefficient (ICC) of 0.90 for myelin-water estimation using a multi-slice GRASE sequence without parallel acceleration (scan time 14:06 min), while acquisition with a parallel acceleration factor of 2 resulted in a slightly worse average within-subject CoV of 6.4% and an average ICC of 0.83 at half the scan time. Hence, a multi-slice GRASE acquisition with parallel acceleration factor 2 and a scan time of 7:30 min still provides an excellent reproducibility.
Related Concept Videos
Water and Mineral Acquisition
Gradually Varying Flow
Rapidly Varying Flow
Accelerators
The effectiveness of calcium chloride can...
Nervous Tissue: Myelin
Schwann cells begin to form myelin sheaths around axons during fetal development. They wrap around a small...
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid: