Comparison of bolus- and filtering-based EIT measures of lung perfusion in an animal model

Symon Stowe1,2, Alistair Boyle1, Michaël Sage3

  • 1Systems and Computer Engineering, Carleton University, Ottawa, Canada.

Abstract

Related Concept Videos

Two-Compartment Open Model: IV Bolus Administration01:18

Two-Compartment Open Model: IV Bolus Administration

The two-compartment model for intravenous (IV) bolus administration illustrates drug distribution in the body, subdividing it into central and peripheral compartments. This model operates on the concept of two-compartment kinetics. The drug's plasma concentration shows a bi-exponential decline following IV bolus administration, signaling the presence of two disposition processes: distribution and elimination.
The disparity between drug input and the sum of drug transfer rates between...
1.1K
One-Compartment Open Model for IV Bolus Administration: General Considerations01:19

One-Compartment Open Model for IV Bolus Administration: General Considerations

The one-compartment model is a pharmacokinetic tool that models the body as a single, uniform compartment, facilitating the understanding of drug distribution and elimination. This model is particularly beneficial for intravenous (IV) bolus administration, where the drug rapidly circulates throughout the body.
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
711
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance00:56

One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance

Clearance is a key pharmacokinetic parameter that quantifies the volume of body fluid from which a drug is entirely removed within a specific time frame. It is crucial in assessing how a drug is eliminated from the body and has critical clinical applications.
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
352
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
974
Pharmacokinetic Models: Comparison and Selection Criterion01:26

Pharmacokinetic Models: Comparison and Selection Criterion

Physiological and compartmental models are valuable tools used in studying biological systems. These models rely on differential equations to maintain mass balance within the system, ensuring an accurate representation of the dynamic processes at play.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
357
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K