Deterioration of Basic Properties of the Materials in FRP-Strengthening RC Structures under Ultraviolet Exposure

Jun Zhao1, Gaochuang Cai2,3, Lu Cui4

  • 1School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001, China. zhaoj@zzu.edu.cn.

Polymers
|April 11, 2019
PubMed

Related Concept Videos

Structural Properties and Dimensions of Lumber01:21

Structural Properties and Dimensions of Lumber

Wood's structural properties derive from fibers aligned along the tree's length, contributing significantly to its mechanical strength. Wood exhibits up to twenty times greater tensile strength along these fibers compared to across them, and generally shows better performance under compression than tension. The length of fibers varies, with hardwoods having fibers around one twenty-fifth inch long and softwoods ranging from one-eighth to one-third inch.
The strength characteristics of...
394
Structure and Physical Properties of Alkynes02:37

Structure and Physical Properties of Alkynes

Introduction:
In nature, compounds containing both carbon and hydrogen are known as "hydrocarbons". Aliphatic hydrocarbons are compounds whose molecules contain saturated single bonds (i.e., alkanes) or unsaturated double or triple bonds. Alkenes contain carbon–carbon double bonds and have a structural formula CnH2n. Unsaturated hydrocarbons containing carbon–carbon triple bonds are called "alkynes" and are structurally represented by the formula CnH2n-2.
The...
13.1K
Mortar Joint Deterioration in Masonry01:13

Mortar Joint Deterioration in Masonry

Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
348
RC Circuit with Source01:15

RC Circuit with Source

When a DC source is abruptly applied to an RC (Resistor-Capacitor) circuit, the voltage can be represented as a unit step function. The voltage across the capacitor, known as the step response, characterizes how the circuit reacts to this sudden change in input.
Due to the inherent properties of a capacitor, its voltage cannot change instantaneously. This means that immediately after the switch is closed, the capacitor's voltage remains the same as it was just before the switch was closed.
2.7K
RC Circuit without Source01:16

RC Circuit without Source

When a DC source is abruptly disconnected from an RC (Resistor-Capacitor) circuit, the circuit becomes source-free. Assuming that the capacitor was fully charged before the source was removed, its initial voltage, denoted as V0, can be considered as the initial energy that stimulates the circuit.
Applying Kirchhoff's current law at the top node of the circuit and substituting the current values across the components, a first-order differential equation is obtained. By rearranging the terms...
2.4K
Applications of RC Circuits01:22

Applications of RC Circuits

A relaxation oscillator is one of the applications of RC circuits. A neon lamp relaxation oscillator comprises a capacitor, a resistor, a voltage source, and a lamp. The lamp acts like an open circuit, with infinite resistance until the potential difference across the lamp reaches a specific voltage. At that voltage, the lamp acts like a short circuit with zero resistance, and the capacitor discharges through the lamp, thus producing light. Once the capacitor is fully discharged through the...
4.0K