Related Experiment Video
Updated: Jan 26, 2026

10:03
Evaluation of Right Ventricular Function in Experimental Models of Pulmonary Arterial Hypertension
Published on: June 27, 2025
763
Pulmonary Function Evaluation in Elite Swimmers: A Case Series of Environmental Considerations
Keenan Robinson1, Thomas Kremen, J Tod Olin
1USA Swimming Colorado Springs, CO.
Current Sports Medicine Reports
|April 11, 2019
Abstract
No abstract available in PubMed .
More Related Videos
09:40Induction of Right Ventricular Failure by Pulmonary Artery Constriction and Evaluation of Right Ventricular Function in Mice
Published on: May 13, 2019
11.1K
04:00Author Spotlight: Assessing the Olfactory Effects of Airborne Pollutants — Buried Food and Social Odor Tests
Published on: September 13, 2024
1.3K
Related Concept Videos
Pulmonary Function Tests
779
Pulmonary Function Tests (PFTs)
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
779
Design Consideration
563
Designing a structure involves a series of considerations, primarily the material's ultimate strength, calculated through tests that measure changes under increased force until the material reaches its breaking point or limit. The ultimate load, where the material breaks, is divided by its original cross-sectional area, resulting in the ultimate normal stress or strength. The ultimate shearing stress is another significant factor taken into account.
The factor of safety is another key...
The factor of safety is another key...
563
Resistors In Series
6.1K
A resistor is an ohmic device that limits the flow of charge in a circuit. Most circuits have more than one resistor. If several resistors are connected together and connected to a battery, the current supplied by the battery depends on the equivalent resistance of the circuit. The equivalent resistance of a combination of resistors depends on both their individual values and how they are connected. The simplest combination of resistors is the series combination.
In a series circuit, the...
In a series circuit, the...
6.1K
Series Resonance
787
The RLC circuit impedance is defined as the ratio of the supply voltage to the circuit current. Resonance in such a circuit occurs when the imaginary part of this impedance equals zero. This specific condition means that the inductive reactance is exactly equal to the capacitive reactance. The frequency at which this happens is known as the resonant frequency. Mathematically, the resonant frequency is inversely proportional to the square root of the product of the inductance (L) and capacitance...
787
Tensile Strength Considerations of Concrete
541
Considering the tensile strength of concrete involves recognizing that the theoretical strength of cement paste can be up to a thousand times higher than what is observed in practical applications. This significant discrepancy is largely attributed to the presence of microscopic cracks within the concrete. These cracks tend to amplify stress at their tips when a load is applied, a phenomenon explained by Griffith's theory of brittle fracture.
The dimensions and shape of a concrete specimen...
The dimensions and shape of a concrete specimen...
541
Transmission Line Design Considerations
617
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
617