Related Experiment Video
Updated: Jan 26, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
Body surface distribution of T wave alternans is modulated by heart rate and ventricular activation sequence in
Behnaz Ghoraani1,2, Adrian M Suszko3, Raja J Selvaraj3
1Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada.
Background:
T wave alternans (TWA) is an electrocardiographic marker of heightened sudden death risk from ventricular tachyarrhythmias in patients with cardiomyopathy. TWA is evaluated from the 12-lead electrocardiogram, Frank lead, or Holter lead recordings, however these clinical lead configurations will not record TWA from adjacent regions of the body torso.
Objective:
We tested the hypothesis that changing heart rate or ventricular activation may alter the body surface distribution of TWA such that the clinical ECG leads fail to detect TWA in some patients; thereby producing a false-negative test.
Methods:
In 28 cardiomyopathy patients (left ventricular ejection fraction 28±6%), 114 unipolar electrograms were recorded across the body torso during incremental atrial pacing, followed by atrioventricular pacing at 100, 110 and 120bpm. TWA was measured from each unipolar electrogram using the spectral method. A clinically positive TWA test was defined as TWA magnitude (Valt) ≥1.9 uV with k ≥3 at ≤110bpm.
Results:
Maximum Valt (TWAmax) was greater from the body torso than clinical leads during atrial (p<0.005) and atrioventricular pacing (p<0.005). TWAmax was most prevalent in the right lower chest with atrial pacing 100 bpm and shifted to the left lower chest at 120 bpm. TWAmax was most prevalent in left lower chest with atrioventricular pacing at 100 bpm and shifted to the left upper chest at 120 bpm. Using the body torso as a gold standard, the false-negative rate for clinically positive TWA with clinical leads was 21% during atrial and 11% during atrioventricular pacing. Due to TWA signal migration outside the clinical leads, clinically positive TWA became false-negative when pacing mode was switched (atrial→atrioventricular pacing) in 21% of patients.
Conclusions:
The body surface distribution of TWA is modulated by heart rate and the sequence of ventricular activation in patients with cardiomyopathy, which can give rise to modest false-negative TWA signal detection using standard clinical leads.
More Related Videos
10:08Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine
Published on: February 17, 2018
09:11Implantation of Radiotelemetry Transmitters Yielding Data on ECG, Heart Rate, Core Body Temperature and Activity in Free-moving Laboratory Mice
Published on: November 21, 2011
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Factors Affecting Drug Distribution: Organ Perfusion Rate
Perfusion rate-limited distribution relies on the...
Pharmacokinetics in Pediatric Patients: Drug Distribution
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy