Related Experiment Video
Updated: Jan 26, 2026

VirWaTest, A Point-of-Use Method for the Detection of Viruses in Water Samples
Published on: May 11, 2019
Confirming the need for virus disinfection in municipal subsurface drinking water supplies
M B Emelko1, P J Schmidt1, M A Borchardt2
1Department of Civil and Environmental Engineering, University of Waterloo, 200 University Ave. W. Waterloo, Ontario, N2L 3G1, Canada.
Abstract:
Enteric viruses pose the greatest acute human health risks associated with subsurface drinking water supplies, yet quantitative risk assessment tools have rarely been used to develop health-based targets for virus treatment in drinking water sourced from these supplies. Such efforts have previously been hampered by a lack of consensus concerning a suitable viral reference pathogen and dose-response model as well as difficulties in quantifying pathogenic viruses in water. A reverse quantitative microbial risk assessment (QMRA) framework and quantitative polymerase chain reaction data for norovirus genogroup I in subsurface drinking water supplies were used herein to evaluate treatment needs for such water supplies. Norovirus was not detected in over 90% of samples, which emphasizes the need to consider the spatially and/or temporally intermittent patterns of enteric pathogen contamination in subsurface water supplies. Collectively, this analysis reinforces existing recommendations that a minimum 4-log treatment goal is needed for enteric viruses in groundwater in absence of well-specific monitoring information. This result is sensitive to the virus dose-response model used as there is approximately a 3-log discrepancy among virus dose-response models in the existing literature. This emphasizes the need to address the uncertainties and lack of consensus related to various QMRA modelling approaches and the analytical limitations that preclude more accurate description of virus risks.
Related Concept Videos
Confirmation Biases
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
What are Viruses?
The Water Cycle
Nerve Supply of the GI Tract
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...
Blood Supply to the Digestive System
Blood Supply to the Digestive System: The splanchnic circulation involves three main arteries: the celiac artery (also known as the celiac trunk) and the superior and inferior mesenteric...

