Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative
Shengzhen Tao1, Kishore Rajendran1, Wei Zhou1
1Department of Radiology, Mayo Clinic, Rochester, MN, United States of America.
Abstract:
Multi-energy CT acquires simultaneous multiple x-ray attenuation measurements from different energy spectra which facilitates the computation of virtual monoenergetic images (VMI) at a specific photon energy (keV). Since the contrast between iodine attenuation and the attenuation of surrounding soft tissues increases at lower x-ray energies, VMIs in the range of 40-70 keV can be used to improve iodine visualization. However, at lower energy levels, image noise in VMIs is substantially increased, which counteracts the benefits from the increased iodine contrast, resulting in a decreased iodine contrast-to-noise ratio (CNR). There exists considerable data redundancy between multi-energy CT images created from the same acquisition. Similarly, a substantial spatio-spectral data redundancy exists between multi-energy CT images and the corresponding VMIs. In this work, we develop a denoising framework that exploits this data redundancy to improve iodine CNR in the VMIs. We accomplish this by applying prior-knowledge-aware iterative denoising to low-energy VMIs; we refer to the denoised images as mono-PKAID images. The proposed framework was evaluated using phantom and in vivo data acquired on a research whole-body photon-counting-detector CT, as well as using data from a commercial dual-source dual-energy CT system. The results of phantom experiments show that the proposed framework can preserve image resolution and noise texture compared to the original VMIs, while reducing noise to improve iodine CNR. Quantitative measurements show that the iodine CNR of 50 keV VMI is improved by 1.8-fold using the proposed method, relative to the VMI produced using commercial software (Mono+). With mono-PKAID, VMIs at lower keV take full advantage of higher iodine contrast without substantially increasing image noise. These observations were confirmed using patient data sets, which demonstrated that mono-PKAID reduced image noise, improved CNR in anatomical regions with iodine perfusion by 1.8-fold, and potentially enhanced the visibility of focal liver lesions.
More Related Videos
Related Concept Videos
Self-Awareness and Its Effects
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Subconsciousness and No Awareness
An illustrative example of subconscious processing is its role in problem-solving. Often, individuals...
High-Level and Low-Level Awareness
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...