Safety evaluation of cable barriers installation on rural highways in British Columbia
Mohamed El Esawey1, Caitlin Sowers1, Joy Sengupta1
1a British Columbia Ministry of Transportation and Infrastructure , Victoria , British Columbia , Canada.
Objective:
The objective of this study was to evaluate the safety effectiveness of cable barrier systems installation on rural highway sections in British Columbia, Canada.
Methods:
Data on police-attended serious collisions (injury + fatality) on a number of rural highway sections in British Columbia, Canada, were used in the analysis. An empirical Bayes (EB) approach was employed to ensure that the evaluation results were reliable and to account for the regression to the mean artifact. Safety performance functions (SPFs) were developed using data collected at similar sites. For both median cable barrier (MCB) and roadside cable barrier (RCB) sections, the evaluation was undertaken using all serious collisions, truck serious collisions, and off-road serious collisions.
Results:
For MCB sections, the evaluation results showed statistically significant reductions of 21.7, 53.8, and 34.8% in all serious collisions, truck serious collisions, and off-road left (ORL) combined with head-on (HO) serious collisions. For RCB sections, statistically significant reductions of 74.7, 100, and 100% were found in all serious collisions, truck serious collisions, and off-road right (ORR) serious collisions, respectively. The impact of the after period on the evaluation results was explored. It was found that the changes in safety become more stable using an after period of 2-5 years.
Conclusions:
Cable barriers were successful in reducing the frequency of serious collisions on provincial highways in British Columbia.
Related Concept Videos
Cable: Problem Solving
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Survey Safety
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load