Comparison of T1 mapping and fixed T1 method for dynamic contrast-enhanced MRI perfusion in brain gliomas
G M Conte1, L Altabella1, A Castellano1
1Neuroradiology Unit and CERMAC, Vita-Salute San Raffaele University and IRCCS San Raffaele Scientific Institute, Via Olgettina 60, 20132, Milan, Italy.
Objectives:
To compare dynamic contrast-enhanced MRI (DCE-MRI) data obtained using different prebolus T1 values in glioma grading and molecular profiling.
Methods:
We retrospectively reviewed 83 cases of gliomas: 46 lower-grade gliomas (LGG; grades II and III) and 37 high-grade gliomas (HGG; grade IV). DCE-MRI maps of plasma volume fraction (Vp), extravascular-extracellular volume fraction (Ve), and tracer transfer constant from plasma to tissue (Ktrans) were obtained using a fixed T1 value of 1400 ms and a measured T1 obtained with variable flip angle (VFA). Tumour segmentations were performed and first-order histogram parameters were extracted from volumes of interest (VOIs) after co-registration with the perfusion maps. The two methods were compared using Wilcoxon matched-pairs signed-rank test and Bland-Altman analysis. Diagnostic accuracy was obtained and compared using ROC curve analysis and DeLong's test.
Results:
Perfusion parameters obtained with the fixed T1 value were significantly higher than those obtained with the VFA. As regards diagnostic accuracy, there were no significant differences between the two methods both for glioma grading and molecular classification, except for few parameters of both methods.
Conclusions:
DCE-MRI data obtained with different prebolus T1 are not comparable and the definition of a prebolus T1 by T1 mapping is not mandatory since it does not improve the diagnostic accuracy of DCE-MRI.
Key Points:
• DCE-MRI data obtained with different prebolus T1 are significantly different, thus not comparable. • The definition of a prebolus T1 by T1 mapping is not mandatory since it does not improve the diagnostic accuracy of DCE-MRI for glioma grading. • The use of a fixed T1 value represents a valid alternative to T1 mapping for DCE-MRI analysis.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Fixed Action Patterns
Fixing Double-strand Breaks