Carotid Artery Stenting in Acute Stroke Using a Microporous Stent Device: A Single-Center Experience
Anthony Lamanna1, Julian Maingard2, Hong Kuan Kok3
1Interventional Radiology Service, Department of Radiology, Austin Hospital, Melbourne, Australia.
Background:
Carotid artery stenting (CAS) is an established treatment for carotid artery stenosis, typically in a semielective or elective setting. The growth of mechanical thrombectomy for acute stroke has led to an increased use of emergent carotid artery stenting (eCAS). This single-center retrospective case series evaluates the safety and efficacy of eCAS using a dual-layer micromesh nitinol stent to treat carotid artery stenosis in the acute stroke setting.
Methods:
Ethics approval was granted by the institutional review board. Clinical data of all patients who underwent CAS using the Casper dual-layer micromesh nitinol stent system (MicroVention, Terumo, Tustin, California, USA) at a tertiary level 24-hour endovascular thrombectomy service over a 2-year period (June 2016-June 2018) were retrospectively obtained and reviewed.
Results:
Twenty eCAS procedures were performed in 19 patients over the study period. Most patients had tandem lesions (12/20; 60%). Median National Institute of Health Stroke Scale score on admission was 17 (interquartile range 9-22). Stent deployment was technically successful in all patients. Recanalization rate was 95%. Symptomatic intracranial hemorrhage occurred in 2 patients (10%), both resulting in death. No other procedure-related deaths occurred. Stent thrombosis occurred in 2 patients. One delayed embolic stroke occurred. No other stent-related complications occurred. Median National Institute of Health Stroke Scale score at 24 hours postprocedure was 3 (interquartile range 1-12). Six patients had a good clinical outcome (modified Rankin Scale score between 0 and 2) at 3- to 6-month follow-up (38%).
Conclusions:
eCAS using the Casper stenting system is effective and technically feasible in the acute stroke setting, although the ideal antiplatelet and anticoagulation regime is not clearly established.
Related Concept Videos
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Instantaneous Center of Zero Velocity
To analyze this, consider two points on the wheel: point A and point B. The absolute velocity of point B can be expressed as the vector sum of the absolute velocity of point A and the relative velocity of point B with respect to point A. To simplify this analysis,...
Patient-centered Care