Related Experiment Video
Updated: Jan 26, 2026

Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020
Measurement uncertainty and risk of false conformity decision in the performance evaluation of liquid chromatography
Luciana Separovic1, Felipe Rebello Lourenço1
1Departamento de Farmácia, Faculdade de Ciências Farmacêuticas, Universidade de São Paulo, Av. Prof. Lineu Prestes, 580, Bloco 13, CEP 05508-000, São Paulo, SP, Brazil.
Abstract:
Liquid chromatography is one of the main techniques used in pharmaceutical quality control analytical procedures. However, there will always be a measurement uncertainty (MU) associated with them, that can lead to the approval of an out of specification lot (consumer risk) or rejection of a lot within specification (producer risk). Thus, the aim of this study was to evaluate the performance of liquid chromatography analytical procedures based on their measurement uncertainty and to estimate the risk of false conformity decisions. The uncertainties of the analytical procedures were estimated based on the results of validation (trueness and precision). Then, the ratio between overall uncertainty and specification range (U/T%) was calculated. It was noted that in most cases (73%), random errors (precision) contributes more significantly to the overall uncertainty when compared to systematic errors (trueness). Monte Carlo method was used, generating different manufacturing processes scenarios, and analytical results based on the MU of each analytical procedure. Then, consumer's and producer's risks were estimated from the simulated values. Pharmaceutical dosage forms that require more steps in sample preparation had higher measurement uncertainties, often above the recommended target uncertainty. As most of the analytical procedures showed U/T% values above recommended, the majority presented high estimated risk values and did not fit for purpose. Therefore, it is important to considerate the measurement uncertainty as part of analytical procedures validation, since trueness and precision values affect directly the measurement uncertainty and the risk of false conformity decisions.
More Related Videos
07:04A High-performance Liquid Chromatography Measurement of Kynurenine and Kynurenic Acid: Relating Biochemistry to Cognition and Sleep in Rats
Published on: August 19, 2018
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Uncertainty in Measurement: Reading Instruments
Uncertainty in Measurement: Significant Figures