A Personalized 3D-Printed Model for Preoperative Evaluation in Thyroid Surgery
Published on: February 17, 2023
Estimation of thyroid volume from scintigraphy through 2D/3D registration of a statistical shape model
Hongkai Wang1, Dongyu Yu2, Ziyu Tan3,4
1School of Biomedical Engineering, Dalian University of Technology, Dalian, Liaoning 116024, People's Republic of China.
None:
Accurate measurement of thyroid volume is important for thyroid disease diagnosis and therapy. In nuclear medicine, the thyroid volume is usually estimated from scintigraphy images using empirical equations. However, due to the lack of volumetric information from the scintigraphy image, the accuracy of equation-based estimation is imperfect. To solve this problem, this paper proposes a method which registers a 3D thyroid statistical shape model (SSM) to a single-view scintigraphy image to achieve more accurate volume estimation. The SSM was constructed based on a training set of segmented 3D CT images, and the thyroid shape variations between the training subjects were modelled using the point distribution model. For thyroid volume estimation, the SSM was projected into the scintigraphy image of the target patient, and then the projected model shape was nonrigidly registered with the patient's scintigraphy image. The resultant 2D deformation file was back-projected to 3D space to guide the deformation of the 3D SSM. This process was repeated iteratively until convergence, and the volume of the finally deformed SSM was considered as the estimation of the patient's thyroid volume. For validation, this method was evaluated based on a test set of 20 scintigraphy images, achieving an estimation error of -2.10% ± 5.20% which was much less than the error of the conventional equation-based method (35.76% ± 15.20%) based on the same test set. The robustness of this method was further tested using a challenging case, i.e. a scintigraphy image with a large thyroid tumor. For this case, the volume estimation error was only 6.08%. Our method has significantly improved the accuracy of thyroid volume estimation from scintigraphy images, and it will enhance the value of scintigraphy imaging for thyroid disease diagnosis and radioiodine therapy.
Related Concept Videos
Molecular Shapes
Two regions of electron density in a diatomic...
Statistical Significance
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Probability in Statistics
An example of a simple event is a coin toss. The result of a coin toss is either a head or a tail. Here, head and tail are two simple events. These two simple events make up the sample space. Further, the probability of an event occurring falls within the range of 0 to 1. The probability of an...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Introduction to Statistics
In statistics, the collection of individuals or objects under study is called population. The idea of sampling is to select a portion of the larger population...