Background:
There is a widespread belief that spinal anaesthesia in patients with preeclampsia might cause severe hypotension and decreased uteroplacental perfusion. This study aimed to evaluate the incidence and severity of spinal induced-hypotension in preeclamptics and healthy parturients.
Methods:
Total of 78 patients (40 healthy and 38 preeclamptic) undergoing a C-Section with spinal anaesthesia were included. Spinal anaesthesia was performed with a mixture of 8-9 mg isobaric 0.5% bupivacaine, 20 mcg fentanyl and 100 mcg morphine (total volume 2.2-2.4 ml). Blood pressures (BP)-SBP, DBP, MAP were recorded non-invasively before performing spinal anaesthesia and at 2.5 minutes after a spinal puncture.
Results:
The BP falls (%) from baseline were significantly greater in the healthy parturients compared to those with preeclampsia (25.8% ± 10.1 vs 18.8% ± 17.0 for SBP, 28.5% ± 8.8 vs 22.5% ± 10.4 for DBP, and 31.2% ± 14.2 vs 18.2% ± 12.6% for MAP, p < 0.05). The incidence rate of hypotension in the preeclamptics was 25% compared to 53% in healthy parturients (p < 0.001). Higher doses of vasopressors both ephedrine (16.5 ± 8.6 vs 6.0 ± 2.0 mg) and phenylephrine (105 ± 25 mg) in the healthy women were required. There was no need for phenylephrine treatment in the preeclamptic group.
Conclusion:
This study showed that the incidence and severity of spinal-induced hypotension in preeclamptic patients are less than in healthy women. The use of low dose spinal anaesthesia also contributed to this statement.
More Related Videos
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Spinal Cord
The Spinal Cord
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...
Spinal Nerves: Plexus II
The Lumbar Plexus
The lumbar plexus is situated within the lumbar region of the back and is primarily formed by the first four lumbar spinal nerves (L1 to L4). This plexus extends its branches into several nerves, including the...
Cranial and Spinal Meninges
Cranial Meninges
These meningeal layers cover the cranium. The dura mater is the outermost layer of cranial meninges. It is a thick and durable membrane of dense...