Related Experiment Video
Updated: Jan 26, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Time-integrated thermal desorption for quantitative SIFT-MS analyses of atmospheric monoterpenes
Kristýna Sovová1, Anatolii Spesyvyi1, Miroslava Bursová2
1The Czech Academy of Sciences, J. Heyrovský Institute of Physical Chemistry, Dolejškova 3, 18223, Prague 8, Czech Republic.
Abstract:
A new time-integrated thermal desorption technique has been developed that can be used with selected ion flow tube mass spectrometry, TI-TD/SIFT-MS, for off-line quantitative analyses of VOCs accumulated onto sorbents. Using a slow desorption temperature ramp, the absolute amounts of desorbed compounds can be quantified in real time by SIFT-MS and constitutional isomers can be separated. To facilitate application of this technique to environmental atmospheric monitoring, method parameters were optimised for quantification of the three common atmospheric monoterpenes: β-pinene, R-limonene and 3-carene. Three sorbent types, Tenax TA, Tenax GR and Porapak Q, were tested under 26 different desorption conditions determined by the "design of experiment", DOE, systematic approach. The optimal combination of type of sorbent, bed length, sampling flow rate, sample volume and the initial desorption temperature was determined from the experimental results by ANOVA. It was found that Porapak Q exhibited better efficiency of sample collection and further extraction for total monoterpene concentration measurements. On the other hand, Tenax GR or TA enabled separation of all three monoterpenes. The results of this laboratory study were tested with the sample accumulated from a branch of a Pinus nigra tree. Graphical abstract.
More Related Videos
Related Concept Videos
The Integrated Rate Law: The Dependence of Concentration on Time
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Thermal Strain
Thermal Expansion