Related Experiment Video
Updated: Jan 26, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Calculated arterial blood gas values from a venous sample and pulse oximetry: Clinical validation
Magnus Ekström1,2, Anna Engblom2, Adam Ilic2
1Department of Clinical Sciences, Division of Respiratory Medicine & Allergology, Lund University, Lund, Sweden.
Background:
Arterial blood gases (ABG) are essential for assessment of patients with severe illness, but sampling is difficult in some settings and more painful than for peripheral venous blood gas (VBG). Venous to Arterial Conversion (v-TAC; OBIMedical ApS, Denmark) is a method to calculate ABG values from a VBG and pulse oximetry (SpO2). The aim was to validate v-TAC against ABG for measuring pH, carbon dioxide (pCO2) and oxygenation (pO2).
Methods:
Of 103 sample sets, 87 paired ABGs and VBGs with SpO2 from 46 inpatients eligible for ABG met strict sampling criteria. Agreement was evaluated using mean difference with 95% limits of agreement (LoA) and Bland-Altman plots.
Results:
v-TAC had very high agreement with ABG for pH (mean diff(ABG-v-TAC) -0.001; 95% LoA -0.017 to 0.016), pCO2 (-0.14 kPa; 95% LoA -0.46 to 0.19) and moderate to high for pO2 (-0.28 kPa; 95% LoA -1.31 to 0.76). For detecting hypercapnia (PaCO2>6.0 kPa), v-TAC had sensitivity 100%, specificity 93.8% and accuracy 97%. The accuracy of v-TAC for detecting hypoxemia (PaO2<8.0 kPa) was comparable to that of pulse oximetry. Agreement with ABG was higher for v-TAC than for VBG for all analyses.
Conclusion:
Calculated arterial blood gases (v-TAC) from a venous sample and pulse oximetry were comparable to ABG values and may be useful for evaluation of blood gases in clinical settings. This could reduce the logistic burden of arterial sampling, facilitate improved screening and follow-up and reduce patient pain.
More Related Videos
05:33How to Calculate and Validate Inter-brain Synchronization in a fNIRS Hyperscanning Study
Published on: September 8, 2021
07:02A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure
Published on: May 15, 2020
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Standard Free Energy Changes
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Calculating Equilibrium Concentrations
A more...