Related Experiment Video
Updated: Jan 26, 2026

Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
Published on: August 14, 2019
MK-curve - Characterizing the relation between mean kurtosis and alterations in the diffusion MRI signal
Fan Zhang1, Lipeng Ning2, Lauren J O'Donnell1
1Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
Abstract:
Diffusion kurtosis imaging (DKI) is a diffusion MRI (dMRI) technique to quantify brain microstructural properties. While DKI measures are sensitive to tissue alterations, they are also affected by signal alterations caused by imaging artifacts such as noise, motion and Gibbs ringing. Consequently, DKI often yields output parameter values (e.g. mean kurtosis; MK) that are implausible. These include implausible values that are outside of the range dictated by physics/biology, and visually apparent implausible values that form unexpected discontinuities, being too high or too low comparing with their neighborhood. These implausible values will introduce bias into any following data analyses (e.g. between-population statistical computation). Existing studies have attempted to correct implausible DKI parameter values in multiple ways; however, these approaches are not always effective. In this study, we propose a novel method for detecting and correcting voxels with implausible values to enable improved DKI parameter estimation. In particular, we focus on MK parameter estimation. We first characterize the relation between MK and alterations in the dMRI signal including diffusion weighted images (DWIs) and the baseline (b0) images. This is done by calculating MK for a range of synthetic DWI or b0 for each voxel, and generating curves (MK-curve) representing how alterations to the input dMRI signals affect the resulting output MK. We find that voxels with implausible MK values are more likely caused by artifacts in the b0 images than artifacts in DWIs with higher b-values. Accordingly, two characteristic b0 values, which define a range of synthetic b0 values that generate implausible MK values, are identified on the MK-curve. Based on this characterization, we propose an automatic approach for detection of voxels with implausible MK values by comparing a voxel's original b0 signal to the identified two characteristic b0 values, along with a correction strategy to replace the original b0 in each detected implausible voxel with a synthetic b0 value computed from the MK-curve. We evaluate the method on a DKI phantom dataset and dMRI datasets from the Human Connectome Project (HCP), and we compare the proposed correction method with other previously proposed correction methods. Results show that our proposed method is able to identify and correct most voxels with implausible DKI parameter values as well as voxels with implausible diffusion tensor parameter values.
Related Concept Videos
Diffusion
Diffusion
Microsoft Excel: Finding Central Tendency, Skew, and Kurtosis
Mean: The arithmetic average of all data points. It is calculated by adding all the values together and dividing by the number of values. The mean is sensitive to extreme values (outliers).
Median: The middle value when the data points are arranged in ascending or descending...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Paracrine Signaling
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...

