High Flow-Rate Sample Loading in Large Volume Whole Water Organic Trace Analysis Using Positive Pressure and Finely

Ola Svahn1, Erland Björklund2

  • 1Department of Environmental Science and Bioscience, Faculty of Natural Science, Kristianstad University, SE-291 39 Kristianstad, Sweden. ola.svahn@hkr.se.

Related Concept Videos

Design of Columns under a Centric Load01:17

Design of Columns under a Centric Load

The design of columns under centric load is a fundamental aspect of structural engineering and is critical for ensuring the stability and integrity of structures. Euler's and Secant's formulas are central to understanding and calculating the critical load and deformation behaviors of columns, providing a basis for safe and effective structural design.
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
546
Design of Columns under an Eccentric Load01:21

Design of Columns under an Eccentric Load

Designing columns to withstand eccentric loads is a critical aspect of structural engineering, ensuring structures can support off-center loads without failure. This design process must account for the additional normal stresses introduced by eccentric loading, which can significantly influence a column's stress distribution and overall stability. An eccentric load applied to a column induces normal stresses that can be conceptualized as a combination of stresses due to an equivalent...
1.2K
Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
947
Le Chatelier's Principle: Changing Volume (Pressure)02:32

Le Chatelier's Principle: Changing Volume (Pressure)

For gas-phase equilibria, changes in the concentrations of reactants and products can occur with altered volume and pressure. The partial pressure, P, of an ideal gas is proportional to its molar concentration, M.
40.3K
Pressure and Volume in an Adiabatic Process01:27

Pressure and Volume in an Adiabatic Process

Free expansion of a gas is an adiabatic process. However, there are few differences between free expansion and adiabatic expansion. During free expansion, no work is done, and there is no change in internal energy. But, for an adiabatic expansion, work is done, and there is a change in internal energy. During an adiabatic process, the relation between the pressure and volume is obtained from the condition for the adiabatic process, that is,
3.4K
Factors Affecting Drug Distribution: Organ Perfusion Rate01:15

Factors Affecting Drug Distribution: Organ Perfusion Rate

Drug distribution within the body is a complex process influenced by several factors, including perfusion rate, the rate at which the bloodstream transports drugs to tissue. This limitation becomes particularly significant when dealing with highly lipophilic drugs. In such cases, the rate at which the drug can move across membranes is crucial, and if the membrane is highly permeable to the drug, distribution becomes rate-limited by perfusion.
Perfusion rate-limited distribution relies on the...
567