Related Experiment Video
Updated: Jan 26, 2026

Direct Drug Delivery to Kidney via the Renal Artery
Published on: April 17, 2021
Impact of Renal Artery Stent-Graft Placement on Renal Function in Chronic Aortic Dissection
Tzu-Ting Kuo1, Chun-Yang Huang1, Po-Lin Chen1
1Division of Cardiovascular Surgery, Department of Surgery, Taipei Veterans General Hospital, Taiwan; Department of Medicine, School of Medicine, National Yang Ming University, No. 201, Section 2, Shipai Road, Beitou District, Taipei City, Taiwan.
Purpose:
To evaluate the effect of renal stent-graft placement on kidney function and size alternation in chronic aortic dissection.
Materials And Methods:
Twenty-five consecutive patients with chronic aortic dissection after thoracic endovascular aortic repair who underwent renal stent-graft placement between January 2015 and December 2016 were retrospectively reviewed. Forty-three patients with chronic aortic dissection who received thoracic endovascular aortic repair in the same period were reviewed as a control group for kidney volume comparison.
Results:
Twenty-five stent-grafts were deployed over 25 renal arteries. Overall renal function was assessed by the slope of the regression line constructed from the plots of creatinine clearance versus time within 2 years after the procedure (-0.2810 vs -0.3146 mL/min-1/mo-1, P = .868), kidney volume at 12 months (129.4 ± 40.9 vs 137.0 ± 44.2 cm2, P = .193) and effective renal plasma flow at 6 months (106.3 ± 46.9 vs 124.4 ± 55.5 mL/min, P = .050) and was not significantly deteriorated. Seven treated patients (87.5%) with a renal artery supplied by a false lumen had a decrease in kidney volume, as did 14 patients (56%) in the control group (P = .206). Three patients with a dissected renal artery (75%) in the stent-graft group had an increase in kidney volume compared with 1 patient (11.1%) in the control group (P = .052).
Conclusions:
Occlusion of the re-entry tear by a stent-graft in the renal artery remains a safe strategy to promote false lumen thrombosis. The stent-graft poses a potential risk of reducing the kidney volume in kidneys supplied by the false lumen but may provide a positive effect in kidney volume with a concomitant dissected renal artery in chronic aortic dissection.
Related Concept Videos
Serum Studies: Renal Function Tests
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Tubule and Collecting Duct
Proximal Convoluted Tubule (PCT):
The PCT is the initial segment of the renal tubule, extending from the Bowman's capsule that encloses the glomerulus. Its convoluted structure and microvilli-lined cells increase the surface area for reabsorption. The PCT reabsorbs glucose, amino acids, sodium, and water from the filtrate, ensuring essential...

