Related Experiment Video
Updated: Jan 26, 2026

Using Neuron Spiking Activity to Trigger Closed-Loop Stimuli in Neurophysiological Experiments
Published on: November 12, 2019
The devil is in the detail: How a closed-loop documentation system for IV infusion administration contributes to and
Dominic Furniss1, Bryony Dean Franklin2, Ann Blandford1
1University College London, UK.
Abstract:
Many studies have highlighted the patient safety risks in intravenous medication administration, and various technological solutions have been proposed to mitigate those risks, including 'smart pumps' and closed-loop systems. Few studies describe these implementations in detail. In this article, we report on a sociotechnical investigation of a closed-loop documentation system linked with smart pumps for intravenous infusion administration on an intensive care unit. The smart pumps are 'mapped' to an electronic prescribing and medication administration system, allowing infusion rates, volumes and boluses of intravenous medication to be monitored in real time. Ethnographic observations were conducted over 37 h, including direct observation of infusion administration (n = 23 infusions), discussions with clinical staff and semi-structured interviews with intensive care unit managers (n = 2). Analysis was based on the Distributed Cognition for Teamwork (DiCoT) method to understand how information is processed across individuals, teams and technologies. We report on how the system works in context, and identify contributions and compromises to patient safety with new risks that need to be managed at bedside and intensive care unit level.
More Related Videos
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Methods of Documentation IV: Focus Charting
It typically involves three columns for recording information:
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions