Specific detection of avian influenza H5N2 whole virus particles on lateral flow strips using a pair of sandwich-type
Sang Hoon Kim1, Junho Lee1, Bang Hyun Lee1
1Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul, 136-701, Republic of Korea.
Abstract:
We report a selection of a cognate pair of aptamers for whole avian influenza virus particles of H5N2 by using graphene-oxide based systemic evolution of ligands by exponential enrichment (GO-SELEX), and the application of a pair of sandwich-type binding aptamers on the lateral flow strips. The aptamers were characterized by GO-FRET assay, and Kd values of the selected aptamers were estimated to be from 6.913 × 105 to 1.27 × 106 EID50/ml (EID50/ml: 50% egg infective dose). Based on the evidence from confocal laser scanning microscope (CLSM), surface plasmon resonance (SPR), and circular dichroism (CD) spectrum analysis, the aptamers, J3APT and JH4APT, were found to be working as a cognate pair that binds to the target virus at the different sites simultaneously. This cognate pair of aptamers then was successfully applied on the lateral flow strips, clearly showing sandwich-type binding images with the presence of the certain numbers of H5N2 virus particles. On the newly developed lateral flow strips, the target virus was detectable down to 6 × 105 EID50/ml in the buffer and 1.2 × 106 EID50/ml in the duck's feces, respectively, by the naked eye. By using the ImageJ software, the LOD was found to be 1.27 × 105 EID50/ml in the buffer and 2.09 × 105 EID50/ml in the duck's feces, respectively. Interestingly, on the lateral flow strips, enhanced specificity towards the target virus (H5N2) appeared over other subtypes of H5Nx. To the best of our knowledge, this is the first report about the application of the cognate pair of aptamers for the detection of influenza virus on the lateral flow strips. This study shows the promising perspective of a cognate pair of aptamers for the on-site detection system which could be useful for rapid detection of avian influenza viruses for preventing the pandemic influenza viruses from spreading.
More Related Videos
08:10Production of High-Titer Infectious Influenza Pseudotyped Particles with Envelope Glycoproteins from Highly Pathogenic H5N1 and Avian H7N9 Viruses
Published on: January 15, 2020
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Related Concept Videos
Introduction to Types of Flows
Two-dimensional flow involves changes in both length and height, as seen in...
What are Viruses?
DNA Base Pairing
Heat Flow and Specific Heat
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...