Comparison of finite helical axes of normal and anatomically designed prosthetic knees
Shoji Konda1, Tetsuya Tomita2, Takaharu Yamazaki3
1Department of Health and Sport Sciences, Osaka university Graduate school of Medicine, 1-17 Machikaneyama, Toyonaka, Osaka 560-0043, Japan.
Background:
Describing three-dimensional joint motion using the finite helical axis has an advantage in understanding unknown coupling motion in prosthetic knee joints. We aimed to examine the differences in the orientations of finite helical axis of normal and anatomically designed cruciate-retaining and posterior-stabilized prosthetic knees after total knee arthroplasty.
Methods:
Ten normal, 40 cruciate-retaining prosthetic knees of 33 patients and 19 posterior-stabilized prosthetic knees of 14 patients enabling to flex > 120° were analyzed during a squatting motion with deep knee bending. The motion was recorded by a fluoroscopic imaging system, and the pose of the bone and prostheses were determined by an image registration technique. The finite helical axes were calculated using 30° window.
Findings:
The finite helical axis in the early flexion phase of the normal knees had a greater inferior inclination (mean - 19.0° (SD 7.2°)) than those of the cruciate-retaining (mean - 1.7 (SD 5.0°)) and posterior-stabilized (mean - 2.9° (SD 5.5°)) prosthetic knees (p < 0.001), and became almost horizontal and constant in the mid to deep flexion phases. In contrast, the cruciate-retaining and posterior-stabilized prosthetic knees demonstrated slightly inclined and almost constant vertical angles throughout the all phases.
Interpretation:
These results demonstrate that, in the normal knee, a clear coupling motion occurs during the early flexion phase. For the cruciate-retaining and posterior-stabilized prosthetic knees, an unclear coupling motion exists during all phases. These results suggest that the physiological motion is not possible to reproduce using shape-guided motion only even in an anatomically designed prosthetic knee.
Related Concept Videos
Moments of Inertia for an Area about Inclined Axes
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Angular Momentum and Principle Axes of Inertia
To put this equation into simpler terms, it can be reconfigured using rectangular coordinates. This involves choosing an alternative set of XYZ axes that are arbitrarily inclined with respect to the reference frame. The process of deriving the rectangular...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...