Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Heart Failure IV: Classification and Diagnostic Evaluation01:30

Heart Failure IV: Classification and Diagnostic Evaluation

359
Heart failure can be classified in various ways, with the most common classifications based on physical activity limitations, disease progression, severity, and treatment strategies.The Functional Classification of Heart Failure divides patients into four categories based on physical activity limitation due to symptom burden.Class I: Patients in this class have cardiac disease but no physical activity limitations. Ordinary activities like walking, climbing stairs, or routine tasks do not cause...
359
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation01:30

Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation

751
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
751
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

403
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
403
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

321
Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
321
Appendicitis-II: Diagnostic Studies and Management01:29

Appendicitis-II: Diagnostic Studies and Management

548
Diagnosing and managing appendicitis requires a structured and comprehensive approach that spans from initial assessment to postoperative care. Here is an overview of the process:
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
548
Asthma-IV: Diagnostic and Management01:30

Asthma-IV: Diagnostic and Management

3.1K
The diagnosis and management of asthma are comprehensive, encompassing clinical assessments, lung function tests, and pharmacological interventions. Here's an overview:
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
3.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Molecular and Microenvironmental Mechanisms of Malignant Transformation in Benign Salivary Gland Tumors: Implications for Oral Squamous Cell Carcinoma.

Diagnostics (Basel, Switzerland)·2026
Same author

Deciphering site-specific histopathological parameters with potential clinical value in head and neck squamous cell carcinomas.

Oncology letters·2025
Same author

Safety of methylprednisolone irrigation during sialendoscopy: effects on the hypothalamic-pituitary-adrenal axis.

European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery·2025
Same author

Environmental factors associated with autism spectrum disorder in Southern Europe: a systematic review.

International journal of developmental disabilities·2025
Same author

Using deep learning to improve the intelligibility of a target speaker in noisy multi-talker environments for people with normal hearing and hearing loss.

The Journal of the Acoustical Society of America·2024
Same author

Multisensory Fusion for Unsupervised Spatiotemporal Speaker Diarization.

Sensors (Basel, Switzerland)·2024

Related Experiment Video

Updated: Jan 26, 2026

A Tablet-Based Curriculum-Based Measurement Protocol for Kindergarten Writing
15:00

A Tablet-Based Curriculum-Based Measurement Protocol for Kindergarten Writing

Published on: February 7, 2025

1.1K

Development and evaluation of a tablet-based diagnostic audiometer.

Iordanis Thoidis1, Lazaros Vrysis1, Konstantinos Markou2

  • 1a Department of Electrical & Computer Engineering , Aristotle University of Thessaloniki , Thessaloniki , Greece.

International Journal of Audiology
|April 17, 2019
PubMed
Summary

A new mobile app for iPad provides a reliable and valid tool for hearing assessment, offering a feasible alternative to conventional audiometry in clinical practice for pure-tone audiometry.

Keywords:
Behavioural measuresPTAadult or general hearing screeningmobile devices

More Related Videos

Assessment of Age-related Changes in Cognitive Functions Using EmoCogMeter, a Novel Tablet-computer Based Approach
10:13

Assessment of Age-related Changes in Cognitive Functions Using EmoCogMeter, a Novel Tablet-computer Based Approach

Published on: February 14, 2014

14.1K
Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics
10:42

Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics

Published on: June 17, 2022

3.4K

Related Experiment Videos

Last Updated: Jan 26, 2026

A Tablet-Based Curriculum-Based Measurement Protocol for Kindergarten Writing
15:00

A Tablet-Based Curriculum-Based Measurement Protocol for Kindergarten Writing

Published on: February 7, 2025

1.1K
Assessment of Age-related Changes in Cognitive Functions Using EmoCogMeter, a Novel Tablet-computer Based Approach
10:13

Assessment of Age-related Changes in Cognitive Functions Using EmoCogMeter, a Novel Tablet-computer Based Approach

Published on: February 14, 2014

14.1K
Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics
10:42

Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics

Published on: June 17, 2022

3.4K

Area of Science:

  • Audiology
  • Medical Devices
  • Software Engineering

Background:

  • Conventional pure-tone audiometry requires specialized equipment.
  • There is a need for portable and cost-effective hearing assessment solutions.

Purpose of the Study:

  • To develop and validate a mobile software application for pure-tone audiometry.
  • To assess the feasibility of using tablet-based devices in clinical audiology practice.

Main Methods:

  • A mobile application was developed for iPad, adhering to ANSI and IEC standards.
  • Manual and automated air- and bone-conduction audiometry were performed by trained audiologists.
  • Twenty-nine participants underwent testing with both the app and conventional audiometry for validation.

Main Results:

  • The app demonstrated high agreement with conventional audiometry: 90.9% of air-conduction thresholds and 90.8% of air-bone gaps were within 5 dB.
  • Threshold differences between the app and conventional methods were not statistically significant.

Conclusions:

  • The developed audiometric application is a reliable and valid tool for hearing assessment.
  • Mobile devices offer a practical substitute for traditional audiometry in clinical settings, despite certain limitations.