Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
Comparative effectiveness of rapid-cycle ultraviolet decontamination to chemical decontamination on high-touch
Marisol Resendiz1, Timothy S Horseman1, Michael B Lustik1
1Tripler Army Medical Center, Honolulu, HI.
Background:
This quantitative, comparative-descriptive study of inpatient units in a large military medical center was designed to compare the effectiveness of compact ultraviolet (UV-C) decontamination to standard chemical decontamination in reducing the microbial burden on Vocera (San Jose, CA) communication devices and to characterize changes in staff cleaning practices following UV-C device implementation.
Methods:
Aerobic and anaerobic swabs were used to collect microbial samples from Vocera devices (n = 60) before and after chemical decontamination (first sampling) and before and after UV decontamination (second sampling). Cleaning behaviors were assessed by observation and oral inquiry during the baseline sampling and surveyed 8 weeks after UV-C device implementation. Outcomes included aerobic and anaerobic colony-forming units and prevalence of methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, or Clostridium difficile, as determined by standard microbiological methods.
Results:
No differences were found between the two cleaning methods in their ability to reduce aerobic bacteria; however, UV-C was significantly more effective at reducing bacteria grown anaerobically (P < .01). This study elucidated an 8.3% prevalence of methicillin-resistant Staphylococcus aureus on Vocera devices in the inpatient environment. Initially, 42% of respondents reported deviations from manufacturer's cleaning guidelines, and 16.7% reported daily or more frequent cleaning of the Vocera devices.
Conclusions:
After implementation, UV-C decontamination reduced average cleaning time by 43% and increased the rate of daily Vocera cleaning to 86.5%. Respondents reported an overall 98% user satisfaction with the UV-C device.
More Related Videos
Related Concept Videos
Barriers to Effective Communication I
Communication barriers include the following:
Physiological barriers: They are limitations caused by a person's health condition or disability, such as hearing loss, poor eyesight, illness, or unconsciousness. An example to overcome this...
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...
Communication
Effects of Chemicals: Overview
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Responses to Gravity and Touch