Related Experiment Video
Updated: Jan 26, 2026

Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
COMPARISON OF RADIOFREQUENCY ABLATION AND CURETTAGE IN OSTEOID OSTEOMA IN CHILDREN
Ferdi Göksel1, Ayşe Aycan2, Cenk Ermutlu3
1Çanakkale Onsekiz Mart University, School of Medicine, Department of Orthopaedics and Traumatology, Çanakkale, Turkey.
Objective:
Osteoid osteoma, which is observed in the adolescent and young adult population as benign bone tumors, appears as a single nidus with a diameter < 2 cm and is treated with open surgery. However, technological advances in medicine have made it possible to apply less invasive procedures in surgery.
Methods:
Between 2006-2014, 24 patients < 18 years of age were treated for osteoid osteoma. Patient demographic data, surgical data, complications, and recurrences were noted.
Results:
Twenty-four patients (mean age, 11 [2-18] years) were treated and followed up for a mean 3.58 (range, 1-9) years. Mean patient age in the curettage group was 12.1 (range, 3-18) years. Mean operation length was 69.5 (range, 60-120) minutes. Mean hospital stay was 1.3 (range, 0-2) days. Mean patient age in the radiofrequency ablation (RFA) group was 10.7 (range, 2-17) years. Five patients were female and 8 were male. Mean operation length was 49.6 (range, 20-90) minutes. Mean hospital stay was 0.3 (range, 0-1) days. Mean follow-up time was 1.76 (range, 1-4) years. Mean operation length, hospital stay, and follow-up were significantly shorter in the RFA group.
Conclusions:
Considering reduced costs due to shorter hospitalization periods and the ability to reach anatomically difficult locations, percutaneous procedures are likely to replace the conventional open approach.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits