Related Experiment Video
Updated: Jan 26, 2026

Induction and Micro-CT Imaging of Cerebral Cavernous Malformations in Mouse Model
Published on: September 4, 2017
Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A
Lei Zhao1, Jiaqi Bao2, Youmin Guo3
1Department of Radiology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, P.R. China.
Abstract:
Atherosclerotic diseases are systemic and patient outcomes depend on comprehensive imaging evaluation. Computed tomography angiography (CTA) is a powerful tool used to assess atherosclerosis. However, the scanning protocol is designed for cardiovascular and cerebrovascular imaging, which require considerations into the radiation dose, contrast agent and image quality. The purpose of the present study was to evaluate ultra-low dose one-step CTA for coronary, carotid and cerebral arteries with a low concentration contrast agent. A total of 78 patients were enrolled and randomly divided into two groups: Group A (n=38) and B (n=40). High-pitch CTA for coronary, carotid and cerebral arteries with a tube voltage of 70 or 80 kVp and 40 ml contrast agent (270 mgI/ml) was performed by a 128-slice dual-source CT scanner for group A. Standard high-pitch CTA with a tube voltage of 100 kVp and 60 ml contrast agent (370 mgI/ml) was conducted for group B. The image quality, radiation dose and amount of contrast agent in group A were evaluated and compared with group B. The dose length product for groups A and B was 62.95±21.54 vs. 160.15±15.13 mGy cm, respectively (t=-23.157, P<0.001). The mean total iodine content was 10.8±0 mg for group A and 22.2±0 mg for group B. In total, 99.4% of the arterial segments could be assessed for the two groups (χ 2=0.267, P=0.606). The results revealed that ultra-low dose one-step high-pitch CTA can provide assessable image quality, and minimize the radiation dose and contrast agent.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology