Quantitative analysis of effects of the grid specifications on the quality of digital radiography images
1R&D, JPI Healthcare, Co., Ltd., 43, Seonggok-ro 22beon-gil, Ansan-si, Republic of Korea. leesh@jpi.co.kr.
Abstract:
A grid is one of the key components of a digital radiography (DR) system because it removes scattered radiation, which arises when X-rays penetrate an object and improves diagnostic accuracy by enhancing image quality. With the widespread use of DR systems, demand for grids with high precision has simultaneously increased. Because unsuitable grids may decrease image quality and lead to misdiagnosis, using optimised grids for DR systems is critical. In this study, we aimed to analyse the quality of X-ray images acquired using grids with different specifications and proposed standardised criteria for grid use on the basis of our results. We measured modulation transfer function (MTF), normalised noise power spectrum (NNPS) and detective quantum efficiency (DQE) using grids with different ratios (10:1, 12:1 and 15:1) with or without implementing poly methyl methacrylate (PMMA) phantoms (0-20 cm). Pixel pitch of the detector used in this experiment was 143 μm. Based on this, a grid with a line frequency of 85 line pairs/cm was selected to prevent distortion caused by implementing unoptimised grids. As a result, the NNPS was found to increase when using the grid, and the difference in MTF and DQE was only measured when the scattered X-ray was generated by stacking the PMMA phantom. However, grids showed a positive effect MTF and DQE when the PMMA phantom was implemented. Specifically, MTF and DQE improved with increase in grid ratio. Thus, it is desirable to use a high-ratio grid to improve image quality.
More Related Videos
07:38Multimodal Quantitative Phase Imaging with Digital Holographic Microscopy Accurately Assesses Intestinal Inflammation and Epithelial Wound Healing
Published on: September 13, 2016
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Quality of Water
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Framing Effects
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...