Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
Accelerated interleaved spiral-IDEAL imaging of hyperpolarized 129 Xe for parametric gas exchange mapping in humans
Brandon Zanette1,2, Giles Santyr1,2
1Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
Purpose:
To demonstrate the feasibility of mapping gas exchange with single breath-hold hyperpolarized (HP) 129 Xe in humans, acquiring parametric maps of lung physiology. The potential benefit of acceleration using parallel imaging for this application is also explored.
Methods:
Six healthy volunteers were scanned with a modified spiral-IDEAL sequence to acquire gas exchange-weighted images using a single dose of 129 Xe. These images were fit with the model of xenon exchange (MOXE) on a voxel-wise basis calculating parametric maps of lung physiology, specifically: air-capillary barrier thickness (δ), alveolar septal thickness (d), capillary transit time (tx ), pulmonary hematocrit (HCT), and alveolar surface area-to-volume ratio (SVR). An accelerated version of the sequence was also tested in subset of 4 volunteers and compared to the fully sampled (FS) results.
Results:
Mean image-wide values calculated from MOXE parametric maps derived from FS dissolved 129 Xe spiral-IDEAL images were: δ = 0.89 ± 0.17 μm, d = 7.5 ± 0.5 μm, tx = 1.1 ± 0.2s, HCT = 28.8 ± 2.3%, and SVR = 140 ± 16 cm-1 , in good agreement with previously published values based on whole-lung spectroscopy of healthy human subjects. Parallel imaging sufficiently reduces artifacting in accelerated images, but increases disagreement with MOXE parameters derived from FS data with mean voxel-wise unsigned relative differences of: δ = 39 ± 9%, d = 22 ± 3%, tx = 117 ± 43%, HCT = 11 ± 2%, and SVR = 31 ± 12%.
Conclusion:
Dissolved HP 129 Xe spiral-IDEAL imaging for gas exchange mapping is feasible in humans using a single breath-hold. Accelerated gas exchange mapping is also shown to be feasible but requires further improvements to increase quantitative accuracy.
More Related Videos
Related Concept Videos
Gas Exchange and Transport
Gas Laws: Boyle's, Gay-Lussac, Charles', Avogadro's, and Ideal Gas Law
Ideal Gas Equation
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Kinetic Theory of an Ideal Gas
The number of molecules in one mole is called...
Heat Capacities of an Ideal Gas II