Accuracy of cone-beam computed tomography for syndesmosis injury diagnosis compared to conventional computed
Marion Hamard1, Angeliki Neroladaki1, Ilias Bagetakos1
1Division of Radiology, Department of Imaging and Medical Informatics, Geneva University Hospitals, University of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Geneva 14, Switzerland.
Background:
Syndesmosis injury can lead to ankle mortise instability and early osteoarthritis. Several multiple detector computed tomography (MDCT) methods for measurement have been developed. Weight-bearing cone beam CT (WB CBCT) is an emerging technique that offers the possibility of upright-position scanning and lower doses. This study sought to assess the diagnostic accuracy of WB CBCT in syndesmose injury compared to MDCT, with instability confirmed via manual testing upon arthroscopic examination.
Methods:
Three musculoskeletal radiologists with different levels of expertise prospectively analyzed 11 MDCT and eight WB CBCT scans of the same trauma-afflicted ankles with clinical suspicion of syndesmosis lesion over a period of 5 months. They evaluated 10 methods of measurement in both sides. Syndesmosis was considered pathological on arthroscopic examination in four patients. Correlation between readers was evaluated with intra-class correlation testing (p < 0.05 was considered significant). Capacity of discrimination was assessed by area under the curve (AUC) for all methods.
Results:
Inter-observer agreement was near excellent for both WB CBCT and MDCT for the anterior tibio-fibular (TF) distance (ICC = 0.781 and 0.831, respectively), posterior TF distance (ICC = 0.841 and 0.826), minimal TF distance (ICC = 0.899 and 0.875), and TF surface (ICC = 0.93 and 0.84). AUC were better for MDCT than WB CBCT in assessing syndesmosis instability for: anterior TF distance (ROC = 0.869 vs. 0.555, p = 0.01), minimal TF distance (ROC = 0.883 vs. 0.608, p = 0.02) and antero-posterior fibular translation (ROC = 0.894 vs. 0.467, p = 0.006).
Conclusions:
MDCT demonstrated better ability to distinguish pathological syndesmosis than WB CBCT, with the antero-posterior fibular translation the best discriminating measurement. The physiological widening of the contralateral syndesmosis occurring with the WB CBCT upright position may explain these results.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....