A Comparison of Methods to Count Breathing Frequency
Atsushi Takayama1,2, Taro Takeshima3, Yutaka Nakashima4
1Department of Family Medicine, Iwakuni Municipal Miwa Hospital, Iwakuni, Yamaguchi, Japan. m05054at@live.jp.
The breathing time measurement method offers a more accurate and reliable way to assess patient respiratory rates compared to the 15-second quadruple method. This quick screening tool reduces medical staff workload while maintaining precision in breathing frequency counts.
Area of Science:
- Medical Diagnostics
- Respiratory Physiology
- Clinical Measurement
Background:
- Assessing breathing frequency is crucial in patient care.
- A full-minute breath count can be labor-intensive for healthcare professionals.
- Efficient and accurate methods for respiratory rate assessment are needed.
Purpose of the Study:
- To evaluate the accuracy of two rapid screening methods for determining breathing frequency.
- To compare the agreement of the 15-second quadruple method and breathing time measurement with a full-minute breath count.
- To identify a more efficient method for respiratory rate assessment.
Main Methods:
- A cross-sectional study involving 57 nurse examiners and 1 nurse acting as a patient.
- Comparison of three methods: 1-minute breath count, 15-second quadruple method, and breathing time measurement.
- Statistical analysis including correlation and Bland-Altman analyses, and paired t-tests.
Main Results:
- The breathing time measurement method showed a higher correlation (0.90) with the 1-minute breath count than the 15-second quadruple method (0.83).
- Bland-Altman analysis revealed better agreement for breathing time measurement (bias: 0.5 ± 2.6 SD, limits of agreement: ±5.0) compared to the 15-second quadruple method (bias: -2.1 ± 2.9 SD, limits of agreement: ±5.6).
- Statistically significant differences were found between both rapid methods and the 1-minute breath count (P < .001).
Conclusions:
- The breathing time measurement method demonstrates superior agreement with the gold standard 1-minute breath count.
- This method is a more reliable and accurate quick screening tool for respiratory rate assessment.
- The findings support the adoption of breathing time measurement to reduce workload and improve efficiency in clinical settings.
Related Concept Videos
Breathing
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Dose Size and Dosing Frequency: Determination Methods
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Frequency-dependent Selection
Mechanism of Breathing II: Expiration
Expiration, or exhaling, is a complex physiological process that begins as the inspiratory muscles begin to relax. This relaxation triggers a series of events that epitomize the efficiency of the respiratory system.
Mechanism of Expiration: